CONVERSION EQUATION SETUP Examples

{4,1,1,0,0,12,34}

4 = CONVERSION EQUATION SETUP
1 = Conversion equation 1
1 = Polynomial
0 = No display of units
0 = Constant K

o

12 = Constant K

1

34 = Constant K

2

{4,2,3,2,2,5}

4 = CONVERSION EQUATION SETUP
2 = Conversion equation 2
3 = Power
2 = Units display (

°

C)

2 = Constant K

o

5 = Constant K

1

Command 5 - DATA RANGE SETUP

Command 5 specifies the channel number and whether sampled data or
post-processed data should be transferred to a connected CFX-9850G. It
also specifies the range of sample data to be transferred to a calculator list or
matrix.

Syntax

{5, Channel Select, Data Select, Data Begin, Data End}

Channel Select Parameter

This parameter specifies the channel from which data should be transferred
to the calculator. The initial default for this parameter is 0.

0

Current send channel

1

Channel 1 (CH1 - analog channel)

2

Channel 2 (CH2 - analog channel)

3

Channel 3 (CH3 - analog channel)

4

Channel 4 (SONIC channel)

5

Channel 5 (DIG IN channel)

6

Recorded time data

• Command 3 must also be used to select absolute or relative time data

whenever 6 (recorded time data) is specified for this parameter.

Data Select Parameter

This parameter specifies which data should be returned to the calculator.
The initial default for this parameter is 0.

Advertising