3 scanner motor unit, 3 scanner motor, Unit ” (p99) – Epson Stylus TX100 User Manual

Page 99

Advertising
background image

Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300

Revision A

DISASSEMBLY/ASSEMBLY

Disassembling the Scanner Unit

99

Confidential

4.6.3 Scanner Motor Unit

† Parts/Components need to be removed in advance:

Document Cover/ASF Cover (

p 59

), Scanner Unit (

p 62

)

Upper Scanner Housing (

p 96

)

† Removal procedure

1. Move the Scanner Carriage Unit to the center.

(Refer to 4.6.2 Scanner Carriage Unit Step1 (p97))

2. Loosen the Scanner Timing Belt by pressing the Driven Pulley and remove

the Scanner Timing Belt from the Combination Gear and the Driven Pulley.

(Refer to 4.6.2 Scanner Carriage Unit Step3 (p97))

3. Release the Scanner Motor cable from the ribs at the bottom of the Scanner

Housing.

4. Remove the two screws that secure the Scanner Motor Unit, and remove the

Scanner Motor Unit.

Figure 4-114. Removing the Scanner Motor Unit

Scanner Motor Unit

Scanner Motor cable

SCREW S-TIGHT M3x5 BIND

Positioning hole and dowel

Protrusion
Rib

„ When installing the Scanner Motor Unit, align each dowel at

the bottom of the Scanner Housing with their positioning holes
of the Scanner Motor Unit. (See

Fig.4-114.

)

„ Route the Scanner Motor cable through the three ribs and the

two protrusions at the bottom of the Scanner Housing. (See

Fig.4-114.

)