11 TROUBLE SHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
The electric motor is 
running but the pump 
does not suck water 
1. After the pump starts, the pump 
body does not fill with water 
1. Fill the pump with water
 
 
2. Insufficient tightness of the 
suction hose 
2. Check the recommended and 
used pans and components of the 
pump, e.g. joint of the suction 
nose, joint of the pressure hose, 
clamping ring, suction hose, etc., 
including screw sealing strip 
made from Teflon or hemp cord. 
The pump can work only when 
well sealed 
 
 
3. The filter screen of the non-
return valve of the sucking inlet is 
blocked 
3. Clean the non-return of the 
sucking inlet and the filter screen 
 
 
4. The air can't be released from 
the pressure hose because the 
water outlet is closed 
4. When the pump starts sucking, 
open the water outlet (e.g. the 
tap. sprinkling nozzle etc.) 
 
 
5. The waiting time does not 
correspond to the regulations 
5. Fill the whole suction hose with 
water, or recheck it at least 7 
minutes after the pump starts 
 
 
6. Excessive suction head (>8m)
6. Reduce the suction head
 
 
7. The non-return fails to suck 
water 
7. Check the water level of the 
well or the water pool. If possible, 
increase the length of the suction 
hose. 
The electromotor cannot 
run 
1. No power supplied
1. Check the power supply
 
 
2. The ventilator hood obscures 
rotation of the vane 
2. Pull out the power plug, remove 
the ventilator hood with a 
screwdriver, then reinstall it again 
by slightly rotating the vane and 
check to see if it rotates freely 
 
 
3. Fan blocked
3. Pull out the power plug, move 
the shaft with the screwdriver 
through the ventilator hood. If the 
shaft is blocked, send it to a 
service center for inspection 
Insufficient water flow-
out 
1. Excessive suction head (>8m)
1. Check the suction head
 
 
2. The filter screen of the non-
return is blocked 
2. Clean the filter screen
 
 
3. The suction water level lowered 
too much 
3. Immerse the non-return in deep 
water 
 
 
4. Impurities have reduced the 
effective capacity of the pump 
4. Wash the shell of the pump, the 
suction hose and the outlet 
pressure hose with pressurized 
water