Operatings instructions, Technical data – Electrolux 3531 WK-M User Manual
Page 6
 
6
Burner markings
The operating knob has a ring showing 
the scale of markings.
Off.
Max. flame
and ignition position
Min. flame
Operatings instructions
15
Type of gas
Natural, G-20 - 20mbar
Category and pressures
II
2H3+
20 - 28/37 mbar
Max. nominal load Q, H
S
:
Wok burner =
3,9 kW x 1
Total=
3,9 kW
FSD
The unit features fully-secured gas taps
(thermo-fuse).
H
S
= Gross calorific value
Q =
Nominal load
Voltage=
220-240 V AC
Ignition transformer=
50 HZ - 0,6 VA
CE 048 BO- 0039
Radio-noise reduction
This unit observes the current EEC-directive
on radio noise reduction.
This gas appliance is -approved and mar-
ked in accordance with the gas appliance
Directive (90/396/CEE), the low voltage
directive (73/23/CEE) and the EMC directive
(89/336/CEE incl. the agreed directive
changes.
Technical data
The Dropinett must be connected via
an external switch with a contact
gap of min. 3 mm (the main switch
may be used)
Cable type: 0,75 mm² HO5VV-F
N L1
240 V
1N + PE