Enviro ENVIROFIRE 1600 User Manual

Page 10

Advertising
background image

OUTSIDE AIR:

Pedestal

rear

A 4” (10.16 cm) fresh air adapter kit is available. This adapter can be installed either

on the back pedestal or through the floor under the pedestal.

Place the 1/4” mesh screen between the fresh air adapter and the body of the

pedestal. (AS SHOWN)
NOTE: Fresh air connection to the unit must be a non combustible pipe.

(Example: 4” (10.16 cm) single wall aluminum flex pipe)

NOTE: REMOVE THE 4” KNOCK OUT ON THE REAR OF THE
PEDESTAL IF ROOM AIR IS TO BE USED FOR COMBUSTION AIR

ALCOVE

INSTALLATION

;

Model 1000 May be installed with double wall pipe in an alcove up to

4 ft. (1.2 m) deep and at least 7 ft. (2.13 m) high: sides
14” and rear 6”.


Model 1600 May be installed with double wall pipe in an alcove up to 30” (76 cm) deep
and at least 70” (178 cm) high and a minimum width of 48” (122 cm)

FLOOR PROTECTION:

If a stove is installed on a combustible floor, it must have a pedestal attached and be on a NON COMBUSTIBLE
hearth pad extending at least 8” (200 mm) to each side, and 18” (455 mm) to the front as indicated below.

TO INSTALL A LISTED, FACTORY BUILT CHIMNEY.

1.

Set floor protector and stove in location in accordance with the clearances

required above (see previous page).

2.

Mark the position for the ceiling hole by using a plumb bob.

3.

Move this location, if necessary, to avoid floor joists, ceiling rafters while
still maintaining required clearances. (see manufacturer’s label on page
15 or the clearances to combustibles on page 8)

4.

Mark the hole for the outside air kit.

5.

Move the stove out of the way.

6.

Cut a pilot hole in the ceiling.

7.

Cut a hole for the ceiling penetration components and frame in the sides of

the hole in both the ceiling and roof. Check, and follow chimney
manufacturer’s instructions for all of these steps.

8.

Install the support box and chimney through the roof. Install the slip section

for the chimney connector.

9.

Slip the roof flashing over the chimney and secure to the roof, being

careful to keep the pipe centered in the opening. To meet the code, the
chimney must extend above the roof at least 3 FT. (91.44 CM), and 2 FT.
(60.9 CM) above any area of the roof, within 10 FT. (304.8 CM) of the end
of the chimney.

10.

Be sure all pieces including outside rain cap, flange, collar and pipe are

installed and then place the stove back into position.

11.

Install the smoke pipe with the lower (crimped) edge of the pipe inside

the smoke collar. Any creosote formed will then run back down into the
stove. All connections must be tight and secured with three sheet metal
screws equally spaced.

12.

Also install an outside air flex pipe to the stove.

10

Advertising
This manual is related to the following products: