Using LANVIEW
Troubleshooting
4-3
RPS
Off
No power indicated by
either the internal or a
connected external power
supply, or
there is no power
redundancy available
from the external power
supply.
1. Ensure that the power cords are plugged in
correctly and that there is power at the two
power sources.
2. If an external power supply is connected
to the C1H124-48, note the display of its
LED indicators for power status
indications. Correct problem as necessary.
3. Contact Enterasys Networks for technical
support.
Green
Blinking. No power
redundancy from the
external power supply, or
the internal power supply
failed or is not receiving
ac power. However, there
is power redundancy
from the external power
supply.
1. Ensure that the power cords are plugged in
correctly and that there is power at the two
power sources.
2. Contact Enterasys Networks for technical
support.
Solid. Power redundancy
is available from external
power supply. The
system is powered by
either the internal or
external power supply.
None.
Link/
Activity
Off
No link.
No activity or port in
standby.
None.
Green
Solid. Port is linked, but
the interface is not
receiving any traffic.
None.
Blinking. Port linked and
traffic is being received or
transmitted by the
interface.
None.
Table 4-1
LANVIEW LEDs (Continued)
LED
Color
State
Recommended Action