Al336kcl-337015-p6, Industrial fan – Kichler 337015 User Manual

Page 7

Advertising
background image

6

Fig. 11

Ceiling mounting
bracket

Attach
safety cable
to ceiling joist
with screw and
washer

Fig. 12

Industrial Fan

7. ELECTRICAL CONNECTIONS

6. INSTALLATION OF SAFETY SUPPORT

(required for Canadian installation ONLY)

A safety support cable is provided to help
prevent the ceiling fan from falling.

Step 1. Attach the provided wood screw and
washers to the ceiling joist next to the mounting
bracket but do not tighten. (Fig. 11)

Step 2. Adjust the length of the safety cable to
reach the screw and washers by pulling the extra
cable through the cable clamp until the overall
length is correct, put the end of the cable back
through the cable clamp, forming a loop at the
end of the cable. Tighten the cable clamp
securely. Now, put the loop in the end of
the safety cable over the wood screw and under
the washer. Tighten the wood screw securely.

NOTE: Although the safety support cable is
required for Canadian installations only. It's a
good idea to make the attachment with any
installation.

WARNING: To avoid possible electrical shock,
be sure you have turned off the power at the
main circuit panel.

Follow the steps below to connect the fan to
your household wiring. Use the wire connecting
nuts suppled with your fan. Secure the
connectors with electrical tape. Make sure there
are no loose wire strands or connections.

A. OPTIONAL WALL CONTROL WIRING

NOTE: To wire your fan to an "OPTIONAL" wall
speed control following the steps below and
refer to Fig. 12. To wire your fan DIRECTLY to
the power supply, see the instruction on the next
page.

Step 1. Connect the fan supply (black) wire to
the black wire marked "TO MOTOR L" from the
wall switch. (Fig. 12)

Step 2. Step 2. Connect the black household
supply wire to the black wire marked "AC in L"
from the wall switch. (Fig. 12)

Finish the wall switch installation by attaching
the wall switch inside the switch box and
attaching the faceplate.

BLK

BLK

WH

WH

GRN

Wiring
box

TO MOTOR L

AC in L

Ground to
mounting
bracket
or downrod

Power lines 120v

Green ground

Advertising