startIng

warm

engIne

1. Press the decompression device (E).

2. Stop Switch

Move stop switch button (A) forward away from the STOP posi-

tion.

3. Purge Bulb

Pump purge bulb (C) until fuel is visible in the "Clear" fuel return

line.

4. Recoil Starter

Lay the unit on a flat area and keep movable attachment parts clear

of all obstacles. Hold unit firmly and rapidly pull the recoil starter

handle (D) until the engine fires.

NOTE

If engine does not start after 5 pulls, use Cold Start Procedure.

stoppIng

engIne

1. Release throttle trigger and allow to run at an idle speed.

2. Slide ignition switch to “STOP” position.