GB

• Fill with water to the fill point such that

water starts to run out of the filling

screw (11) hole.

• Retighten the filling screw (11).

Operational start-up

• Check that the electrical connec-

tion is 230V ~50Hz

• Check the proper status of the

electrical plug socket and make

sure that the plug socket is suf-

ficiently fused (at least 10 A). In-

sert the pump plug into the plug

socket and the pump is ready for

operation.

• Make sure that moisture or water

never come in contact with the

mains connection.

There is a risk of electrocution.

Starting the unit

• Connect the power cable of the auto-

matic switch (

A

8) to the power sup-

ply.

When you connect the appliance to

the mains, all lamps will first of all

light up.

• Set the On/Off switch (

A

7) to turn on

the unit.

• The “Power On” indicator (

A

19)

will light up to indicate that the unit is

ready to operate.

• The “Pump On” indicator (

A

18) tells

you that the pump is working.

• In the case of water withdrawal, the

automatic switch is activated automati-

cally and switches on the pump in the

event of a pressure drop in the line. If

the water withdrawal is stopped then

the line pressure increases and the au-

tomatic switch automatically switches

off the pump.

• The “Alarm” indicator (

A

16) lights up

when the appliance turns itself off auto-

matically.

Restarting the appliance

• After the equipment is switched off auto-

matically and the “Alarm” display (16)

illuminated, press the restart switch (17).

• If restarting the appliance fails several

times, fill up the pump with new water.

Maintenance

Instructions

Clean and maintain your equipment regu-

larly. This will guarantee its performance

and long durability.

Ask our service centre to carry out

any work that is not described in

these instructions. Use only original

parts.

Pull out the power plug before every

maintenance operation. There is a risk

of electrocution or of injury from mov-

ing parts.

General cleaning instructions

A reduction in pump feed output may be

indicative of a blockage. In case the unit

clogs up, remove the suction and pressure

hoses. Dismantle the automatic switch (20)

and flush water through the threaded hole

on the pump in order to remove the foreign

body.

Any measures above and beyond these,

particularly opening the equipment, are

to be carried out by an electrician. In the

case of repairs, always contact our service

centre.