Cleaning/maintenance – Florabest FGPS 1100 B2 User Manual

Page 9

Advertising
background image

9

GB

(14). Both piecese marked with

a

B

.

3. Attach the adapter (11) to the

water inlet (2) . Both pieces

marked with an

A

.

4. Attach the suction hose connec-

tion water inlet (13) with the seal

ring (12) to the adaptor (11).

Both pieces marked with an

A

.

Fit the water inlet free from air.

5. Fit a pressure hose to the water

outlet (4) Fit the water outlet free

from air.

Air in the suction hose will stop the

garden pump from working prop-

erly.

Filling the pump

Fill up the garden pump every time before

you start using it. This will ensure an im-

mediate start. Running dry will destroy the

pump.

1. Open the filling screw (

9) on the

garden pump.

2. Fill with water to the fill point and

retighten the filling screw (

9).

Checks before initional

operation

• Check that the electrical connec-

tion is 230V ~50Hz

• Check the proper status of the

electrical plug socket and make

sure that the plug socket is suf-

ficiently fused (at least 10 A).

• Make sure that moisture or water

never come in contact with the

mains connection.

There is a risk of electrocution.

• Control the suction hose. The

end of the suction hose must be

placed in water.

• Control the suction hose. The

end of the suction hose must be

in outlet position.

The device is not suitable to be con-

nected to a drinking water supply

system.

Switching ON and OFF

1. Connect the power cable (

6) to the

power supply.

2. Switching On:

On/Off Switch (

5) In position “I

After a suction period the pump begins

the supply of water.

3. Switching Off:

On/Off Switch (

5) In position “0

Overload protection:

In the

event of overload the equipment au-

tomatically switches off. To restart,

allow the equipment to cool then

switch it back on.

Cleaning/Maintenance

Clean and maintain your equipment regu-

larly. This will guarantee its performance

and long durability.

Ask our service centre to carry out

any work that is not described in

these instructions. Use only original

parts.

Pull out the power plug before

every maintenance operation. There

is a risk of electrocution or of injury

from moving parts.