Technical data, General description – Florabest FTP 400 C2 User Manual

Page 5

Advertising
background image

5

GB

Functional description

The pump is fitted with a float switch,

which automatically switches the equip-

ment on or off.

In case of overload, the pump is switched

off by the integrated thermal protection

switch. After cooling, the motor restarts au-

tomatically.

In addition, the pump also has a backflow

stop that prevents water from flowing back,

for example during an interruption in the

power supply.

Technical Data

Submersible water pump .............FTP 400 C2

Mains connection ............ 230 V~, 50 Hz

Power consumption .....................400 W

Max. discharge rate (Qmax) ... 10000 l/h

Max. discharge head (Hmax) ............7 m

Max. depth of immersion ..................7 m

Max. water temperature (Tmax) .......35°C

Hose connection ............ ½“, ¾“, 1“, 1 ½“

(13 mm,19 mm, 25 mm, 38 mm)

Tap connection with

interior thread ................G 1 ½“ (44,9 mm)

Max. foreign body size ...............ø 5 mm

Mains cable ..................................10 m

Weight (incl. accessories) ...approx. 4.0 kg

Safety class ..........................................I

Degree of protection ........................ IPX8

Technical and optical changes can be

carried out in the course of further develop-

ment without notice. All dimensions, refer-

ences and information of this instruction

manual are therefore without guarantee.

Legal claims, which are made on the basis

of the instruction manual, cannot thus be

considered as valid.

for which the equipment is intended or by

incorrect operation.

General Description

The illustration of the principal

functioning parts can be found

on the front foldout page.

Scope of Delivery

Carefully unpack the appliance and check

that it is complete. Dispose of the packag-

ing material correctly.

- Submersible water pump (pump)

-

Angle adapter + adapter with hose

connection

- 8 m nylon rope

- Instructional manual

Overview

1 Carrying handle

2 Mains cable

3 Pump casing

4 Pump base

5 Pump output

6 Float switch

7 Float switch cable

8 Float switch grid

9 Adapter with hose connection

10 backflow stop with seal

(not visible)

11 Angle adapter

12 8 m nylon rope

4a 3 screws, pump base

13 Sealing ring

14 Notch on base

Advertising