Elo TouchSystems 1000 Series User Manual

Page 29

Advertising
background image

C-31

IntelliTouch Touchmonitor Specifications

Mechanical

Positional Accuracy

Standard deviation of error is less than 0.080 in. (2.03 mm).

Equates to less than ±1%.

Touchpoint Density

More than 100,000 touchpoints/in

2

(15,500 touchpoints/cm

2

).

Touch Activation

Typically less than 3 ounces (85 grams).

Force

Surface Durability

Surface durability is that of glass, Mohs’hardness rating of 7.

Expected Life

No known wear-out mechanism, as there are no layers, coatings,

Performance

or moving parts. IntelliTouch technology has been operationally tested

to more than 50 million touches in one location without failure, using

a stylus similar to a finger.

Sealing

Unit is sealed to protect against splashed liquids, dirt, and dust.

Optical

Light Transmission

IntelliTouch 92%, AccuTouch 82%, Surface Capacitive Touch 84%

(per ASTM D1003)

Visual Resolution

All measurements made using USAF 1951 Resolution Chart, under

30X magnification, with test unit located approximately 1.5 in (38 mm)

from sur face of resolution chart. Clear surface: Excellent, with no

noticeable degradation. Antiglare surface: 6:1 minimum.

Gloss (per ASTM

Antiglare surface: Curved: 60 ±20 gloss units or 75 ± 15 gloss units.

D2457 using a 60-

degree gloss meter)