Interface – Epson 1500 User Manual

Page 98

Advertising
background image

INTERFACE

This Level 2 option allows you to change settings for the

built-in interfaces, parallel and serial. This option is not

available for channel 0.

Menu/submenu

INTERFACE

Available options

P (Parallel)

S (Serial) (ActionLaser 1500 only)

The PARALLEL option has these three submenus:

Menu/submenu

CH P CONFIG.

Available options

S L C T I N

AUTOFEED

BUSY DELAY

Normally, you do not need to change these settings. Change

them only when you have special requirements.

SLCT-IN-When you set SLCT-IN to OFF, the printer is

continuously selected and ignores device control codes DC1

and DC3. In almost all cases, leave SLCT-IN set to OFF. When

SLCT-IN is ON, the SLCT-IN signal goes HIGH at power-on

and the control codes DC1 and DC3 are valid.

Menu/submenu

Available options

SLCT-IN

OFF ON or OFF

AUTOFEED-When you set AUTOFEED to OFF, the printer

ignores the AUTOFEED signal on pin 14 and does not send an

automatic line feed (LF) command with each carriage return

(CR). When you set AUTOFEED to ON, the printer adds a line

feed to each carriage return it receives. If your text lines

overprint each other, set AUTOFEED to ON.

Menu/submenu

AUTOFEED

Available options

OFF ON or OFF

4-14 SelecType

Advertising
This manual is related to the following products: