Electrolux 311330813 User Manual

Page 31

Advertising
background image

HOTPLATE

L.P.Gas

R.H.F.

R.H.R.

L.H.R.

L.H.F

Heat Input

1.0kW

2.0kW

2.0kW

2.7kW

(71.85 g/h)

(143.7 g/h)

(143.7 g/h)

(194 g/h)

Injector Marking

051

072

072

083

OVEN

L.P.Gas

Heat Input

2.4kW (172.4 g/h)

Injector Marking

078

Flame Supervision Device

Diamond 'H' GSD 100/30

Thermostat

Diamond 'H' 1100127/B2

Thermostat By-pass Marking

78

GENERAL

Ignition

H.T. Spark

Spark Gap

3-4mm

IMPORTANT - SAFETY REQUIREMENTS

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations
Current Editions. Detailed recommendations are contained in the following British Standard Codes of Practice
- BS.6172, BS.5440: Part 2 and BS.6891. All British Standards must be 'Current Editions'.

PROVISION FOR VENTILATION

This appliance is not connected to a combustion products evacuation device. It shall be installed and
connected in accordance with the current installation regulations. Particular attention shall be given to the
relevant requirements regarding ventilation.
The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2 Current
Edition. All rooms require an openable window or equivalent and some rooms will require a permanent vent
as well. For room volumes up to 5m³ an air vent of 100cm² is required: for room volumes between 5m³ and
10m³ an air vent of 50cm² is required. If the room has a door that opens directly to the outside, no air vent is
required. For room volumes that exceed 11m³ no air vent is required. If there are other fuel burning
appliances in the same room, BS.5440: Part 2 Current Edition should be consulted to determine the requisite
air vent requirements.
If your cooker is in use over a long period of time you may need additional ventilation in your kitchen. This
can be achieved by opening a window or, if an external fan or cooker hood is fitted, switching this on or to a
higher setting.

R E N O W N D E L U X E

32

Advertising