Electrolux DK 9360-9390 User Manual

Page 9

Advertising
background image

69

In the case of abnormal operation, calibration can be carried out

manually:

Manual calibration

Carry out manual calibration in the following cases:

When the hood is installed for the first time.

When power is cut off for many hours or days (e.g. during

prolonged holidays).

When a very rapid change in temperature and/or humidity in the

kitchen takes place.

Carry out calibration with the hob off, at normal ambient tempera-

ture and in the absence of an appreciable amount of steam:

-

press push button A and set the hood OFF (A key OFF)

-

press push buttons A and D simultaneously for 3 secs. The

hood emits a sound signal to indicate calibration taking place.

Sensors test

When functioning in automatic, the system continuously tests the

efficiency of the sensors. In case of damage, it signals the fault,

making the D push button flash the word “SENSOR”. Contact

technical assistance.

In this situation the hood can, in any case, be used in the manual

mode.

Safety procedure

Self-activation of automatic SAFETY functioning in particular

conditions: if the sensors reveal an excessive increase in

temperature, even if the hood is in manual functioning mode,

the system self selects automatic functioning and the extraction

motor starts. The hood can be turned off by pressing push button A.

H - Light ON/OFF

Should the hood or the controls fail to operate: disconnect the power

supply for at least 5 seconds, then turn the hood back on again.

Advertising