NOTE: Retrofit 3-way installations are
likely to include two traveler wires
between the two wall boxes. In new
construction, only one traveler wire Is
required.

3-WAY WIRlNG DIAGRAM:
NEW CONSTRUCTION

6. Place wall control into wall box. Screw

in place and install decorator style
faceplate (included).

7. Next, install the other wall control into

the wall box containing the load wire.
Connect the black wire of the wall
control to the traveler wire(s) already
connected to the black wire (in the
other wall box). Secure with wire
connectors supplied.

11

HOT

BLACK

FAN/LIGHT

WALL

CONTROL

TRAVELER

WIRE

BLK

BLK LOAD

BLACK

GROUND

NEUTRAL

EMERSON

®

EMERSON

®

HI

MED

LOW

FAN OFF

LIGHT

ON

OFF

HI

MED

LOW

FAN OFF

LIGHT

ON

OFF

REMOTE CONTROL
RECEIVER LOCATED
UNDER THE FAN
HOUSING

Figure 17

HOT

BLK

FAN/LIGHT
WALL CONTROL

BLK

TRAVELER WIRES

BLK

BLK

BLACK

LOAD

BLACK

LOAD

TRAVELER WIRES

HOT

BLK

EXISTING

WALL CONTROL

EMERSON

®

EMERSON

®

HI

MED

LOW

FAN OFF

LIGHT

ON

OFF

HI

MED

LOW

FAN OFF

LIGHT

ON

OFF

Figure 18

STANDARD WIRING FOR EXISTING
3-WAY CONTROL

8. Connect one black wire of the wall

control to the “load” (black) wire and
secure with wire connector supplied.

9. Place the second wall control into the

wall box. Screw in place and install
decorator style faceplate (included).
Leave switch in “OFF” mode until fan
installation is completed.

10. Refer to page 4 and complete the

ceiling fan installation.