Warning, Install leveling legs, Level dryer – Electrolux FKGHS01P User Manual

Page 11: Make gas connection

Advertising
background image

11

Install Leveling Legs

1. To protect the floor, use a large flat piece of cardboard from

the dryer carton. Place cardboard under the entire back edge
of the dryer. See illustration.

2. Firmly grasp the body of the dryer (not the console panel).

Gently lay the dryer on the cardboard.

3. Examine the leveling legs. Find the diamond marking.

4. Screw the legs into the leg holes by hand. Use a wrench to

finish turning the legs until the diamond marking is no longer
visible.

5. Place a carton corner post under each of the 2 dryer back

corners. Stand the dryer up. Slide the dryer on the corner
posts until it is close to its final location. Leave enough room
to connect the exhaust vent or gas line.

6. Once connection is made and dryer is in final location,

remove corner posts and cardboard.

For mobile home use

Gas dryers must be securely fastened to the floor at the time of
installation.

Mobile home installations require a Mobile Home Installation Kit.
For more information, please reference the service numbers in
the “Assistance or Service” section of this manual.

Level Dryer

Check the levelness of the dryer. Check levelness first
side to side, then front to back.

If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again for
levelness.

NOTE: It might be necessary to level the dryer again after it has
been moved into its final position.

Make Gas Connection

1. Remove the red cap from the gas pipe. Move the dryer close

to its final position.

2. Using a wrench to tighten, connect the gas supply to the

dryer. Use pipe joint compound on all non-flared male
threads. If flexible metal tubing is used, be sure there are
no kinks.

NOTE: For L.P. gas connections, you must use pipe joint
compound resistant to the action of L.P. gas. Do not use
TEFLON

®†

tape.

A combination of pipe fittings must be used to connect the
dryer to the existing gas line. Shown following is a
recommended connection. Your connection may be different,
according to the supply line type, size and location.

3. Open the shutoff valve in the supply line. The valve is open

when the handle is parallel to the gas pipe.

4. Test all connections by brushing on an approved

noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

A.

³⁄₈

" flexible gas connector

B.

³⁄₈

" dryer pipe

C.

³⁄₈

" to

³⁄₈

" pipe elbow

D.

³⁄₈

" pipe-to-flare adapter fitting

A. Closed valve
B. Open valve

A

B

C

D

A

B

Advertising