Appliances with 2 wires – Electrolux 335 D User Manual

Page 7

Advertising
background image

7

Your appliance must be connected to fixed wiring via the use of
a double pole swiched fused spur outlet with or without pilot
lamp.

We strongly recommend the appliance is connected by a quali-
fied electrician who is a member of the NICEIC who will comply
with the IEE and any local regulations.

NOTE:
The terminology “DOUBLE POLE” means that both the live
and neutral supplies are swiched and disconnected at the
same time.

The terminations labelled SUPPLY are for the connection for
the internal house wiring and the terminations labelled LOAD
are for the appliance.

IMPORTANT

The wires of the mains lead supplied with this appliance are
coloured in accordance with the following code:

Blue-Neutral

Brown-Live

As the colours of the flexible cord of this appliance may not
correspond with the coloured markings identifying the ter-
minals in your plug, proceed as follows: The whire which is
coloured brown must be connected to the terminal which is
marked with the letter L or coloured red.
The wire which is coloured blue must be connected to the
terminal which is marked with the letter N or coloured black.

N

LOAD

L

SUPPLY

L

LOAD

N

SUPPLY

DP 13A, 250V

BLUE

(NEUTRAL)

BROWN

(LIVE)

FUSE

ON

Appliances
with 2 wires