English, Detector cleaning and storage, Detector service – Epson DW076 User Manual

Page 14: Detector troubleshooting

Advertising
background image

English

12

5. Use the marking notches (Y) to accurately mark the position of

the laser beam.

MOUNTING ON A GRADE ROD

1. To secure your detector to a grade rod, first attach the detector

to the clamp by pushing in on the clamp latch (Z). Slide the
tracks on the clamp (AA) around the rail on the detector (BB)
until the latch (CC) on the clamp pops into the latch hole (DD)
on the detector.

2. Open the jaws of the clamp by turning the clamp knob (EE)

counterclockwise.

3. Position the detector at the height needed and turn the clamp

knob clockwise to secure the clamp on the rod.

4. To make adjustments in height, slightly loosen the clamp,

reposition and retighten.

Detector Cleaning and Storage

• Dirt and grease may be removed from the exterior of the

detector using a cloth or soft, non-metallic brush.

Z

AA

BB

CC

EE

DD

• The D

E

WALT digital laser detector is waterproof. If you should

drop the detector in mud, wet concrete, or a similar substance,
simply hose the detector off. Do not use high pressure water,
(e.g., from a pressure washer).

• The best storage place is one that is cool and dry—away from

direct sunlight and excess heat or cold.

Detector Service

Except for batteries, there are no user serviceable parts in the
Digital Laser Detector. Do not disassemble the unit. Unauthorized
tampering with the laser detector will void all warranties.

Detector Troubleshooting

THE DETECTOR WILL NOT TURN ON

• Press and release the power/volume button.
• Check to see that the battery is in place and in the proper

position.

• If the detector is very cold, allow it to warm up in a heated area.
• Replace the 9 volt battery. Turn the unit on.
• If the detector still does not turn on, take the detector to a

D

E

WALT service center.

THE DETECTOR’S SPEAKER MAKES NO SOUND

• Ensure that the detector is on.
• Press the power/volume button. It will toggle from high, to low,

to mute.

• Ensure that the rotary laser is spinning and that it is emitting a

laser beam.

• If the detector is still not making any sound, take it to a D

E

WALT

service center.

THE DETECTOR IS NOT RESPONDING TO MY STATIONARY
LASER LEVEL

• The D

E

WALT Digital Laser Detector has been designed to work

only with rotary lasers.

Advertising