Fig.3 fig.1 fig.2, Specification 3. operation – Sealey SDH20 User Manual

Page 2

Advertising
background image

2. SPECIFICATION

3. OPERATION

Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V 400W

Dehumidifying Capacity:. . . . . . . . . . . . . . . . . . . . . . . . . . 20ltr/day

Working Space: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30mtr³

Maximum Air Flow: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150mtr³/hr

Refrigerant:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R134A

Condensate Tank: . . . . . . . . . . . . . . . . . . . . . . . . 4.5ltr (with Auto Shut-Off

Working Temperature Range:. . . . . . . . . . . . . . . . . . . . . . 5 - 35°C

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14.5kg

This dehumidifier is designed to remove uncomfortable humidity, it can also be used for auxiliary drying of washed clothes indoors.

It is not suitable for keeping the humidity very low. Efficiency of the dehumidifier is influenced by the air outside the room. For operating

efficiently, avoid opening and closing windows and doors. For best performance, operate the dehumidifier within the usable operating

temperature. For safety purposes, the dehumidifying operation will stop automatically - and change to the air cleaning operation - when the

ambient temperature is higher than approximately 35°C.

Ensure that free space around the dehumidifier is kept at all times. Minimum distances of 10cm to the front (water tank location), 20cm to

the sides and rear, and 30cm above are required.

When the unit is switched on, the appropriate Humidity Indicator will light up (High >70%, Medium between 60% and 70%, Low <60%).

This dehumidifier does not have a cooling function, it produces heat during the operation and room temperature will rise. The temperature

will rise when it is operated in a cupboard, or similar. Furthermore, room temperature will rise because doors and windows are closed and

heat is produced from other appliances in the room and from sun radiation. Circulation of the refrigerant may cause some noise within the

dehumidifier when operation is started.

See

figs.1, 2 and 3 for unit layout, controls and mode applications.

3.1.

Automatic Mode

3.1.1.

Set the air vent in either the upward or downward position or open the spot air outlet as required.

3.1.2.

Press On/Off button to turn unit on, Automatic light will be lit and dehumidifying will commence.

3.1.3.

The dehumidifying operation will stop automatically when humidity is below approximately 60%, and change to the air cleaning operation.

3.1.4.

If required set the timer by pressing the Timer button - the order is 2 hours, 4 hours, 8 hours, Off, 2 hours......etc.

3.2.

Continuous Mode

3.2.1.

Set the air vent in either the upward or downward position or open the spot air outlet as required.

3.2.2.

Press On/Off button to turn unit on.

3.2.3.

Press Mode button to select Continuous.

3.2.4.

If required set the timer by pressing the Timer button - the order is 2 hours, 4 hours, 8 hours, Off, 2 hours......etc

3.2.5.

If placing unit in a closet or similar, ensure the water tank faces towards the door and also ensure that the minimum distances of 10cm to

the front, 20cm to the sides and rear, and 30cm above the unit, are adhered to. Also ensure that when closing the door, the power cord is

not trapped.

fig.3

fig.1

fig.2

Original Language Version

SDH20.V3 Issue: 2(SP) - 17/02/14