Fig.1, Introduction, Specification – Sealey IR37 User Manual

Page 2

Advertising
background image

DO NOT leave the heater unattended for prolonged periods of time when in use. Switch the heater off and unplug from the mains

before leaving work area.

DO NOT fill the fuel tank whilst the heater is running or still hot. DO NOT over-fill the fuel container. Wipe up any spilt fuel immediately.

DO NOT obstruct the air inlet (rear) and air outlet (front) of the heater and DO NOT use duct work in front or at the rear of the heater.

DO NOT allow children or animals near the heater when in use, or whilst still hot.

WARNING! RISK OF ELECTRIC SHOCK. DO NOT expose the heater to water spray, rain, dripping water or wind.

DO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.

DO NOT touch the heater outlet or cone when in use, or for a period of time after it’s switched off, as these are VERY hot and will

take time to cool down.

DO NOT switch the heater off by disconnecting it from the mains. ALWAYS set the switch on the burner to the ‘OFF’ position and allow

the cooling cycle to finish, before disconnecting from the mains.

DO NOT use an external fuel tank. Only use the tank that is fitted to the heater, and only fill it when the heater has cooled down.

Ensure that the heater is correctly turned off

When not in use for an extended period, store in a safe, dry area, out of reach of children.

Important:

This appliance is not intended for persons (including children) with reduced physical, sensory or mental capabilities, or lack of

experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person

responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

2. INTRODUCTION

Infrared heater suitable for well ventilated indoor applications. Clean burning unit operates on paraffin, kerosene or diesel. Unit produces an

impressive 125,000 Btu/hr on highest setting. 53ltr tank allows a max. of 20

hrs running time dependant on setting, making this unit extremely

economical. Complies with rigorous standards and is fitted with a safety cut-out.

3. SPECIFICATION

Model

IR37.V3

Heat Output

28 / 37 kW

Rating

95,000 / 125,000 BTU/hr

Fuel

Paraffin / Kerosene / Diesel

Running Time Per Filling (Max)

20 hrs

Fuel Tank Capacity

53 Litres

Heated Area

25000ft³ / 708m³

Voltage / Hz

230V / 50Hz

Rated Amps

5A

Net Weight

33 Kg

Green (Power on)

Flashing Red (Misfire)

Power

Off.

High

Setting

Low

Setting

Fuel Gauge and

Filler Cap

3 Position Switch on

Control Panel

Heater Module (under carriage removed)

Fig.1

WARNING! This heater is not suitable for use with

Bio-Diesel; use of Bio-Diesel will damage

the filter and seals.

Damage caused by use of Bio-Diesel will

not be covered by warranty.

Tips on ignition:-

The photocell is sensitive to sunlight, ignite in the shade.

Listen for fan followed by pump, after switch position " "

Priming essential when new, see 5.5.4.

Observe the fuel level in the filter bowl.

Clean fuel requires clean reservoir and clean transfer cans.

Original Language Version

IR37.V3 Issue:4(I) - 18/02/15

© Jack Sealey Limited

Advertising