4. OPERATION

4.1.

Regulator - The output pressure is controlled by the knob. Before pressurising air system for the first time lift and rotate knob anticlockwise

to remove any loading on the regulator spring. Pressurise the system and then rotate knob clockwise to set required output pressure,

as shown on gauge. When the required pressure is achieved lock knob by pushing down.

Note: For correct pressure setting always adjust upwards from a lower pressure. Therefore to

reset from 90 to 70psi, for example, reduce pressure from 90 to 60psi and then increase

from 60 to 70psi.

4.2.

Filter - The bowl will automatically drain each time the system pressure drops to zero.

However, if the fluid level reaches the maximum mark but the system is to remain

pressurised the bowl can be manually drained by pushing the drain stub upward. Note

that the stub is designed to take a flexible tube so that the waste fluid can be piped away.

4.3.

Lubricator - Remove filler plug (fig.2.A) and fill bowl with air tool oil. This can be done

with air line pressurised.

With air flowing through the lubricator the oil delivery rate can be adjusted by screw ‘B’

whilst watching the drip rate through the sight dome ‘C’. The oil delivery rate will be

automatically increased or decreased in line with the air flow.

5. ADDITIONAL FITTINGS

6. DECLARATION OF CONFORMITY

The following fittings are available from your local Sealey supplier:

SA1/1414 . . . . . . . . . .1/4”BSP-1/4”BSP male-male nipple

SA1/1212 . . . . . . . . . .1/2”BSP-1/2”BSP male-male nipple

SA1/3814F . . . . . . .3/8”BSP-1/4”BSP male-female reducer

SA1/1214F . . . . . . .1/2”BSP-1/4”BSP male-female reducer

SA1/1238F . . . . . . .1/2”BSP-3/8”BSP male-female reducer

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

SA2001/FR/F/L - 1 - 161001

Declaration of Conformity

We, the sole importer into the UK, declare that the products listed here are in conformity with the following standards and directives.

The construction files for these products are held by the Manufacturer and may be inspected, by a national

authority, upon request to Jack Sealey Ltd.

For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.

Filter/Regulator/Lubricator,

Filter/Regulator, Filter & Lubricator.

Models: SA2001, SA2001/FR, SA2001/F

& SA2001/L

97/23/EC Pressure Equipment Directive

98/37/EC Machinery Directive

Signed by Mark Sweetman

Date 19th October 2001

fig. 2

Advertising
This manual is related to the following products: