InstructIons for:

Gas weldinG/cuttinG kit

Model no:

sGa1.v3

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,

give you years of trouble free performance.

1. saFetY instRuctiOns

IMPORTANT: Please Read tHese instRuctiOns caReFullY. nOte tHe saFe OPeRatiOnal ReQuiReMents, waRninGs and cautiOns. use tHe

PROduct cORRectlY and witH caRe FOR tHe PuRPOse FOR wHicH it is intended. FailuRe tO dO sO MaY cause daMaGe and/OR PeRsOnal inJuRY

and will invalidate tHe waRRantY. Please keeP instRuctiOns saFe FOR FutuRe use.

contents

1) torch Handle

2) Hose check Valve, oxygen (normal r.H. thread)

3) Hose check Valve, Acetylene (reverse l.H. thread)

4) cutting Attachment

5) cutting nozzle 1/32”

6) cutting nozzle 3/64”

7) cutting nozzle 1/16”

8) nozzle cleaning tools

9) Mixer nozzle

10) Welding nozzles no. 2, no. 5, no. 10

11) spark lighter

12) regulator oxygen twin gauge single stage (Blue code)

13) flash Arrestor oxygen (Blue code)

14) regulator Acetylene twin gauge single stage (red code)

15) flash Arrestor Acetylene (red code)

16) Hoses, 2, 3/8” x 1.5mtr, complete with fittings

(these are stored in the lid, not shown here)

Always have a fire extinguisher nearby.

never use oxygen or fuel gas to blow soot or dirt from your clothes.

dO nOt wear ragged clothes, as sparks can ignite the ragged or

loose ends.

Always wear goggles or a helmet with the appropriate shade lens.

dO nOt use shaded safety spectacles or unshaded face shield

visors for cutting or welding. they

dO nOt stop the harmful rays

which cause eye damage.

use gauntlet type gloves made from heat resistant material.

secure cylinders to a trolley, wall or post to prevent them from falling.

All cylinders should be used and stored in an upright position.

never drop or strike a cylinder.

dO nOt use cylinders that have

been dented.

cylinder caps should be used when storing or moving cylinders.

empty cylinders should be kept in specified areas and clearly

marked

‘eMPtY’.

never use oil or grease on any inlet connections, outlet connections

or cylinder valves.

examine hoses for cuts, burns or worn areas before each use.

Also inspect fittings for damage. If any damage is found, replace

immediately.

dO nOt repair hose with tape.

Always use reverse flow check valves on torch and flashback

arrestors on the regulator. this greatly reduces the possibility of

mixing gases in the regulator or hoses. reverse flow check

valves are an important safety precaution.

Working pressure on the acetylene regulator should

neveR be

set above 15psi (1bar).

Keep all threads and unions clean and free from oil, dirt or grease.

never apply oil or grease to any thread.

these instructions cover the use of the kit on mild steel. if

used on any other materials, extra precautions will have to

be taken.

Make sure that there is a good flow of air to the user and the tip, at all

times. use a welding fume extractor if conditions are poor or space is

confined.

never leave the gun alight and unattended.

for safety advice regarding gas bottles (oxygen and acetylene)

refer to the supplier of the bottles.

Make sure bottle keys are in place at all times so that in the event

of an emergency the valves can be turned off quickly.

Keep hoses away from flame at all times. Make sure that hoses

are laid flat where possible and not in a position where they can be

run over by vehicles, which would result in permanent damage.

leakinG HOses can kill. leak test all connections and

valves prior to each use of the equipment.

If hoses are not long enough, join them together with the

manufacturer’s couplings only.

dO nOt join damaged hoses, they must be replaced immediately.

remember at all times

Blue = oxygen ‘o’

Red = Acetylene ‘A’

At no time may you interchange parts contained in this kit with those

of other manufacturers.

only sealey replacement items should be used.

Acetylene fittings have a left-handed thread and notches on hose

unions to indicate this.

the regulators in this kit have no user-serviceable parts. All

repairs/calibrations must only be undertaken by a BcgA

approved service agent.