Sealey WPB050 User Manual

Page 4

Advertising
background image

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7Ar

www.sealey.co.uk

W e b

email

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to

www.sealey.co.uk, email [email protected] or phone 01284 757500.

Environmental Protection.

recycle unwanted materials instead of disposing of them as

waste. All tools, accessories and packaging should be sorted,

taken to a recycle centre and disposed of in a manner which

is compatible with the environment.

WEEE Regulations.

Dispose of this product at the end of its working life in compliance

with the Eu Directive on Waste Electrical and Electronic Equipment.

When the product is no longer required, it must be disposed of in an

environmentally protective way. contact your local solid waste

authority for recycling information.

Original Language Version

© Jack Sealey Limited

PROBLEM CAUSE

SOLUTION

Sudden loss of flow.

Loose or leaking connection to the

Check pipeline and correct.

inlet

pipe.

undue vibration or noise.

Suction head is too high and

check suction head and lower the position

causing

cavitation.

of

the

pump.

Excessive flow of water.

Decrease flow of water.

resistance in inlet pipeline.

check pipe and clean out as necessary.

Loose rotating component.

return to your dealer for repairs.

Installation of pump is not stable.

Stop pump and reposition.

Air pocket in pump or pipeline.

release drain plug in impeller housing to release air.

Damaged impeller.

return to your Sealey dealer for repair.

Pump switches on and off

Low air pressure.

check pressure.

rapidly.

Membrane damaged.

return to your Sealey dealer for repair.

Pump switches on and off when

Leak in output side.

Investigate and rectify.

no water is being drawn.

non-return

valve

faulty.

check

and

rectify.

Pump does not switch off.

Pressure switch faulty.

return to your Sealey dealer for repair.

no water at pump inlet.

check for blockage.

faulty

impeller.

Dismantle

and

investigate.