Problem

Possible Cause

Corrective Action

1. PTO is engaged.

1. Disengage the PTO.

2. Speed control lever is are not in neutral

lock position.

2. Ensure the speed control lever is in the

neutral lock position.

3. OPC levers are released.

3. Depress OPC levers.

4. Battery does not have a full charge.

4. Charge the battery. See Check

Battery Charge and Recommended
Jump Starting Procedure
sections in
Maintenance.

5. Electrical connections are corroded, loose

or faulty.

5. Check the electrical connections for

good contact. Clean connector terminals
thoroughly with electrical contact cleaner,
apply dielectric grease and reconnect.

6. Fuse is blown.

6. Replace the blown fuse.

Starter does not crank.

7. Relay or switch is defective.

7. Contact an Authorized Service Dealer.

1. Engine oil level is low.

1. Check and add oil if necessary.

2. LPG tank is overfilled.

2. Take tank to an approved LPG provider

to bleed off some fuel.

3. LPG tank is not an Exmark approved

vapor tank.

3. Remove tank and replace with an Exmark

approved LPG vapor tank.

4. Engine is flooded.

4. Shut off fuel valve. Let unit set for 15-30

minutes. With the valve still off and the
throttle in the “SLOW” position, start the
unit. Once the engine attempts to start,
slowly open the fuel valve.

5. Oil pressure switch or fuel shut-off

solenoid malfunction.

5. Contact an Authorized Service Dealer.

6. Connection to the LPG tank is loose.

6. Hand-tighten connector to tank.

7. LPG fuel tank is empty or very low.

7. Replace the LPG fuel tank.

8. Fuel valve is closed.

8. Slowly open the fuel valve.

9. Fuel valve opened to fast.

9. Open the fuel valve slowly to equalize

pressure in the tank(s).

10. LPG tank is not installed properly.

10. Reinstall the LPG tank.

11. LPG tank components or hoses are dirty

or damaged.

11. Replace LPG tank components or hoses.

12. The throttle is not in the correct position.

12. Be sure the throttle control is in the

“SLOW” position.

13. Air cleaner is dirty.

13. Clean or replace the air cleaner element.

14. Electrical connections are corroded, loose

or faulty.

14. Check the electrical connections for

good contact. Clean connector terminals
thoroughly with electrical contact cleaner,
apply dielectric grease and reconnect.

15. Relay or switch is defective.

15. Contact an Authorized Service Dealer.

Engine will not start, starts hard, or fails to
keep running.

40

Advertising
This manual is related to the following products: