Spanning Tree – Enables/disables STA on this interface. (Default: Enabled)
Priority – Defines the priority used for this port in the Spanning Tree Protocol. If

the path cost for all ports on a switch are the same, the port with the highest priority
(i.e., lowest value) will be configured as an active link in the Spanning Tree. This
makes a port with higher priority less likely to be blocked if the Spanning Tree
Protocol is detecting network loops. Where more than one port is assigned the
highest priority, the port with lowest numeric identifier will be enabled.
• Default: 128
• Range: 0-240, in steps of 16

Admin Path Cost – This parameter is used by the STA to determine the best path

between devices. Therefore, lower values should be assigned to ports attached to
faster media, and higher values assigned to ports with slower media. (Path cost
takes precedence over port priority.)
(Range: 0 for auto-configuration, 1-65535 for the short path cost method

20

,

1-200,000,000 for the long path cost method)
By default, the system automatically detects the speed and duplex mode used on
each port, and configures the path cost according to the values shown below. Path
cost “0” is used to indicate auto-configuration mode. When the short path cost
method is selected and the default path cost recommended by the IEEE 8021w
standard exceeds 65,535, the default is set to 65,535.

20. Refer to “Configuring Global Settings” on page 6 for information on setting the path cost

method.

Table 11-1 Recommended STA Path Cost Range

Port Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Fast Ethernet

10-60

20,000-2,000,000

Gigabit Ethernet

3-10

2,000-200,000

Table 11-2 Recommended STA Path Costs

Port Type

Link Type

IEEE 802.1D-1998

IEEE 802.1w-2001

Fast Ethernet

Half Duplex

Full Duplex

Trunk

19

18

15

200,000

100,000

50,000

Gigabit Ethernet

Full Duplex

Trunk

4

3

10,000

5,000

Table 11-3 Default STA Path Costs

Port Type

Link Type

IEEE 802.1w-2001

Fast Ethernet

Half Duplex

Full Duplex

Trunk

200,000

100,000

50,000

Gigabit Ethernet

Full Duplex

Trunk

10,000

5,000