12. Trouble-shooting
If your device fails to function as required,
please try this checklist first. Perhaps there is
only a minor problem, and you can solve it
yourself.
DANGER! Risk of electric shock!
Do not attempt to repair the device
yourself under any circumstances.
13. Technical
specifications
Subject to technical modification.
14.Warranty of the
HOYER HandelGmbH
Dear Customer,
your device is provided with a 3 year war-
ranty starting with the purchase date. In the
event of product defects, you are entitled to
statutory rights against the vendor. These
statutory rights are not restricted by our war-
ranty presented in the following.
Warranty conditions
The warranty period starts with the purchase
date. Please keep the original purchase re-
ceipt in a safe place. This document is re-
quired to verify the purchase.
Fault
Possible causes/
Action
No function
• Has the device been
connected to the pow-
er supply?
• Check the connection.
The cooking
zone is not
heating up
• No cooking vessel on
the cooking zone2?
• Is the cooking vessel
suitable for induction
cooking zones?
Error message
E 1 on the dis-
play
• No cooking vessel on
the cooking zone2?
• Unsuitable cookware
on the cooking zone?
• Cooking vessel not
placed centrally on the
cooking zone?
Error messages
E 2 to E 7
• Contact the Service
Centre (see chapter
Warranty)
Model:
SIKP 2000 B1
Mains voltage:
220-240 V ~ 50/60 Hz
Protection class: II
Power rating:
Max. 2000 W
Fault
Possible causes/
Action
__RP90248_B5.book Seite 39 Montag, 4. März 2013 9:01 09