Technical data, Safety instructions, 1 terms used – Silvercrest STV 45 C2 User Manual

Page 39: 2 general information

Advertising
background image

STV 45 C2

37

3. Technical data

Power supply:

220 - 240 V

~

/ 50/60 Hz

Maximum power:

45 watts

Protection class:

I I

4. Safety instructions

4.1 Terms used

The following signalling terms are found in
these Operating Instructions:

Warning!
High risk. Disregarding the
warning may cause injury to life
and limb.

Caution!
Medium risk. Disregarding the warning may
cause damage to property.
Note:
Low risk. Circumstances that should be taken
into account when dealing with this
appliance.

4.2 General information

• Before using the appliance, be sure to

read these Operating Instructions
carefully. They are a component part of
the appliance and must be available at
all times.

• Use the appliance only for the purpose

described (see “1.1 Intended purpose”
on page 36).

• Check whether the mains voltage (see

type plate on the appliance) agrees with
your mains voltage.

• This device is not intended to be used by

individuals (including children) with
limited physical, sensory or mental
capabilities or with a lack of experience
and/or lack of knowledge, unless
supervised by a person responsible for
their safety or they have received
instructions from such a person as to
how to use the device. Children should
always be supervised to ensure that they
do not play with the device.

• If there should be any malfunctions, the

appliance may only be repaired by our
Service Centre. The contact data can be
found in “Service Centre” on page 43.

Description

Symbol

Value

Unit

Maximum fan flow rate

F

16,98 m

3

/min

Fan power input

P

38,9

W

Service value

SV

0,44

(m

3

/min)/W

Standby power consumption

Psb

0

W

Fan sound power level

Lwa

55

dB(A)

Maximum air velocity

c

2,17

m/s

Measurement standard for service value

IEC 60879:1986+(corr.1992)

RP96066 Tower-Ventilator LB1 Seite 37 Donnerstag, 10. Oktober 2013 10:45 10