Esc/vp21 command formats, Set command format, Get command format – Epson EMP-X56 User Manual

Page 4: Null command, Illegal commands, Source 21, Vol inc, Source, Source = 21

Advertising
background image

ESC/VP21 Command User's Guide for Business Projectors

4 of 25

2.ESC/VP21 Command Formats

2.1.Set command format

A set command consists of a command and a parameter. Projector returns a colon after executing the command.
There are two types of parameters. One is fixed such as ON, OFF, or 21.Other is a step parameter such as INC, DEC or INIT.

INC increments the parameter by one.
DEC decrements the parameter by one.
INIT initializes the parameter.

Set command example 1

: SOURCE 21

Colon from projector Command Space Parameter Return

Set command example 2

: VOL INC

Colon from projector Command Space Parameter Return

2.2.Get command format

A get command consists of a command and ?. Projector returns a response parameter after executing the command.

Get command example

: SOURCE?

Colon from projector Command ? Return

Response parameter example

SOURCE = 21
:

Colon from projector Command = Parameter

2.3.Null command

The null command is a command code of the return key code (Hex 0D). Projector returns a colon. The null command can be used to confirm
that the projector is in operation.

2.4.Illegal commands

Projector returns “ERR” and a return key code (Hex 0D) and a colon when it receives invalid commands.


ERR
:

Advertising