Problems/ causes/ solutions

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

6. PROBLEMS / CAUSES / SOLUTIONS

ATTENTION:
All repairs must be carried out exclusively by

a specialised technician, with the stove

completely cold and the electric plug pulled

out.

PROBLEM

POSSIBLE CAUSES

REMEDY

Pellets not being fed
into the combustion
chamber.

• Pellet hopper empty.

• Feeder screw blocked by sawdust.


• Reduction motor defective.

• Defective electronic board.

• Refill pellet hopper.

• Empty the hopper and manually free the

feeder screw of sawdust.

Replace reduction motor.

Replace electronic board.

The fire goes out or the
stove stops
automatically.

• Pellet hopper empty.

• Pellets not being fed in.

• Intervention of pellet temperature sensor.

• Door not closed properly or gaskets

worn.

• Unsuitable pellets.

• Low pellet feed rate.

• Combustion chamber dirty.

• Smoke outlet obstructed.

• Pressure switch cuts in.

• Smoke extraction motor failed.

• Refill pellet hopper.

• See previous problem..

• Let the stove cool down completely, reset

the thermostat till lockout ceases, relight
stove; if problem persists, contact
technical assistance.

• Close the door

or replace the gaskets

with original spare parts.

• Change to a type of pellet recommended

by the manufacturer.

Have the fuel feed rate checked by

technical service.

• Clean the combustion chamber, following

instructions in the manual.

• Clean the smoke duct.

Check if smoke duct is blocked and if

the pressure switch is operating
correctly.

Check the motor and replace if

necessary.

The stove runs for a
few minutes and then
goes out.

• Lighting cycle not completed.

• Temporary failure of electricity supply.

• Smoke duct obstructed.

• Temperature sensors defective or broken.

• Sparkplug failure.

• Re-run lighting cycle.

• See previous instruction.

• Clean smoke duct.

Check and replace sensors as

necessary.

Check the plug and replace if

necessary.

Pellets build up in
grate, door glass gets
dirty and flame is weak.

• Insufficient combustion air.




• Pellets damp or unsuitable.

• Smoke extractor motor broken.

• Check that the room air intake is present

and free.

• Check that the combustion air filter on the

pipe Ø 5 cm for air inlet is not obstructed.

• Clean the grate and check that all the

airways are clear.

• Carry out a general cleaning of the

combustion chamber and the smoke duct.

• Check the state of the door gaskets.

• Change the type of pellet.

Check the motor and replace if

necessary.