Operating area – MCZ Athos HYDRO 14 kW User Manual

Page 13

Advertising
background image

PELLET STOVES

Chapter 2

INSTALLATION AND USE MANUAL

page

13

Theoretical notions for installation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

2.2. OPERATING AREA

For proper functioning and good temperature distribution, the stove

should be positioned in a location where it is able to take in the air

necessary for combustion of the pellets (about 40 m

3

/h must be

available), as set forth in the standard governing the installation and in

accordance with local national standards.

The volume of the room must not be less than 30 m

3

.


The air must come in through permanent openings made in walls (in

proximity to the stove) which give onto the outside, with a minimum

cross-section area of 100 cm

2

.

These openings must be made in such a way that it is not possible for

them to be obstructed in any way.
Alternatively, the air can be taken from rooms adjacent to the one

which needs ventilating, as long as they are provided with an air intake

from the outside, and are not used as bedrooms or bathrooms, and

provided there is no fire risk such as there is for example in garages,

woodsheds, and storerooms, with strict compliance with the provisions

of current standards.

It is not permissible to install the stove in bedrooms,

bathrooms or showers, or in a room where another

heating appliance is installed (fireplace, stove etc.)

which does not have its own independent air intake.
Locating the stove in a room with an explosive

atmosphere is prohibited.

The floor of the room where the stove is to be

installed must be strong enough to support its

weight.



If the walls are not flammable, position the stove with a clearance to

the rear of at least 10 cm.
In the case of walls made of flammable material, maintain a minimum

clearance to the rear of 20 cm, a clearance to the sides of 50 cm, and a

clearance to the front of 150 cm. If the room contains objects which

are believed to be particularly delicate, such as curtains, sofas and

other furniture, their distance from the stove should be considerably

increased.

If the flooring is made of wood, provide a floor

protection surface in compliance with current

national standards.

Figure 4 - Example of installation with Polar stove

Figure 5 - Example of installation with Polar stove

Advertising
This manual is related to the following products: