Smart wireless thum adapter – Emerson 00825-0100-4075 User Manual

Page 22

Advertising
background image

Quick Installation Guide

00825-0100-4075, Rev DA

July 2011

Smart Wireless THUM Adapter

22

Hazardous Locations Certificates

North American Certifications

Factory Mutual (FM) Approvals

I5

FM Intrinsically Safe and Non-incendive
Intrinsically Safe for Class I/II/III, Division 1, Groups A, B, C, D, E, F, and G.
Zone Marking: Class I, Zone 0, AEx ia llC
Temperature Codes T4 (-50 °C

T

amb

70 °C)

Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Intrinsically safe and non-incendive when installed according to Rosemount Drawing
00775-0010.
Enclosure Type 4X/IP66

CSA - Canadian Standards Association

I6

CSA Intrinsically Safe
Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D.
T3C (-50 °C

T

amb

70 °C)

Intrinsically safe when installed according to Rosemount Drawing 00775-0012.
Suitable for Class I, Division 2, Groups A, B, C, and D.
Enclosure Type 4X/IP66

European Certifications

I1

ATEX Intrinsic Safety
Certificate No.: Baseefa09ATEX0125X

II 1G

Ex ia IIC T4 (-50 °C

T

amb

70 °C)

IP66

1180

Special conditions for safe use (X)
The surface resistivity of the antenna is greater than one gigaohm. To avoid electrostatic
charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
The enclosure is made of aluminium alloy and given a protective polyurethane paint
finish; however, care should be taken to protect it from impact or abrasion if located in a
zone 0.

N1 ATEX Type n

Certificate No.: Baseefa09ATEX0131

II 3 G

Ex nA IIC T4 (-50 °C

T

amb

70 °C)

Ui = 45 Vdc MAX
IP66

1180

Table 2. Input Parameters

Loop Power

Ui = 30 V
Ii = 200 mA
Pi = 1.0 W
Ci = 0
Li = 0