TURNING THE HEATER OFF

1 Press the ON / OFF button

21

. The red lamp flashes for about 8 seconds and the

heater is turned off. Always check that the flame goes out.

The ventilator continues operating for about 3 minutes after turning off in order
to cool the inside of the heater. If you turn off the power earlier, uncontrolled
symptoms can occur (release of smoke, smell etc.)..

H

IN CASE OF PROBLEMS

The symptoms mentioned above are not faults and not abnormal.
Check the list.

Symptoms

Causes

While igniting

Igniting is tedious

Igniting takes about 45 seconds.

After filling the tank, wait till

the fuel has reached the fixed

tank. Repeat ignition 2 or 3

times.

Crackling sound

This sound is made by the elec-

tric ignition.

White smoke

This can happen if the fuel does

not circulate past the burner

properly

During ignition

or turning off

Smoke and an unpleasant smell

during first use

That is the protective lacquer

getting warm. This soon stops.

Give the space more ventila-

tion.

The ambient temperature does

not increase and the requested

temperature is higher.

The space is too large.

The flame glows red.

The ambient air is damp or salty

or it contains too many impu-

rities.

The ambient temperature does

not decrease and the requested

temperature is lower.

The heater is being used in a

small insulated space or the

outside temperature is relati-

vely high. Turn the heater off.

The displayed ambient tempe-

rature is not the same as indica-

ted by a thermometer.

This is because the displayed

ambient temperature is an indi-

cation of the average tempera-

ture of the space.

Small knocking noises when the

heater is in operation or imme-

diately after turning off.

This is the sound of the metal

expanding.

Noise 8 seconds after turning

off.

A ticking sound: can occur

when the heater cools off.