Technical data – Qlima P126 User Manual

Page 100

Advertising
background image

To prevent unnecessary expense, we recommend that you always first carefully
consult the instructions for use. Take the air conditioner to your dealer for repairs
if these instructions do not provide a solution.

L

TECHNICAL DATA

To be used as indication, subject to modifications

Model

P126

P129

Cooling capacity*

W

2600

2900

EE Class*

A

A

EER*

2.6

2.61

Power consumption

kW

1.0

1.11

Power consumption Standby mode

W

<0.5

<0.5

Current nom.

A

4.35

4.8

Mains

V/Hz/PH

220-240 / 50 / 1

220-240 / 50 / 1

Air delivery max.

m3/h

295

312

Dehumidification max. **

L/24h

30

34

Room size

m3

65 - 90

70 - 95

Compressor type

rotary

rotary

Refrigerant

type/gr

R-410A / 540

R-410A / 620

Thermostat range

°C

16 - 32

16 - 32

Fan speeds

3

3

Max. Sound pressure level / power
level

dB(A)

52 / 65

52 / 65

Dimensions (w x h x d)

mm

435 x 770 x 430

435 x 770 x 430

Weight

kg

28

29

Unit protection

IP X0

IP X0

Remote control

yes

yes

3M

TM

HAF filter

yes

yes

Active carbon filter

yes

yes

Fuse rating

3.15A / 250V

3.15A / 250V

* Conform EN 14511-2011
** Moisture removal at 32°C, 80% RH

Do not dispose of electrical appliances as unsorted municipal waste, use separate
collection facilities. Contact your local government for information regarding the
collection systems available. If electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the groundwater and get into the food
chain, damaging your health and well-being. When replacing old appliances with
new once, the retailer is legally obligated to take back your old appliance for dis-
posal at least for free of charge.

Environmental information: This equipment contains fluorinated greenhouse
gases covered by the Kyoto Protocol. It should only be serviced or dismantled by
professional trained personnel.