3. WIRING

4. DIP SWITCH OPTIONS

Terminal Application

"+" "-" Power Connection

Connect to power supply between (+) and (-) terminal. (Voltage must be between 12-30 VAC or DC)

"NC,C,NO"

Contact Output Wiring

Wiring to an Access Control System

Basic Connection: Magnetic Lock Only

During motion detection, power is removed from
the magnetic lock. The relay behaves according
to the Fail Safe/Fail Secure definition.

Spike Protection

Add a diode or bridge rectifier for locks
that are not spike protected.

D

iode

/

B

rid

g

e

R

e

c

tif

ier

Note: It is recommended to set the
Relay Timer Activation to 1/2
second.

"R" Input Terminal Wiring

Parallel Door Control

(iREX or iREX

Plus)

Use to control the door both from the
iREX or from an external device (card
reader, keypad) usually placed on the
other side of the door.

(Dip Switch settings

on iREX Plus)

Remote iREX Disable (IQ feature) *

Use the Intelligent Queuing feature to remotely
enable or disable the iREX from a remote device
(such as a floor switch, additional PIR, Keycard,
Burglar alarm system, etc.). The iREX will only
activate by motion if the "R" terminal is open, or
for 10 seconds after it closes. The iREX is
disabled when the "R" input is closed after a
delay of 10 seconds.

Remote Buzzer Control *

Use this wiring option to control the iREX
buzzer from a remote contact. Buzzer is
activated while R is open. Turning the
buzzer on does not affect the relay.

Wiring the Remote Buzzer Control
to an Access Control System*

Access Controller

12 - 30 Volt

DC or AC

Power

Supply

+

_

NC

C NO NC C NO

T

T

D

R

-

+

Input

Output

"D" Input Terminal Wiring *

Door Alarm Mode *

If the door is forced open or left open for 10
seconds the buzzer turns on.

Door Secure Mode *

When the iREX is activated but the door remains closed, the relay will drop out after
ten seconds. When the iREX is activated and the door is opened and then closed, the
relay will drop out after 2 seconds.

Maglock

+

_

NC

C

NO

NC

C

NO

T

T

D

R

-

+

Door Contacts

(Normally Closed)

Other Inputs

12 - 30 Volt

DC or AC

Power

Supply

+

_

Notes: Relay Timer Mode must be set for at least 16 seconds

The Door Alarm Mode is not to be considered as a UL listed Burglar Alarm System.

"T" Tamper Switch Wiring *

The tamper terminals are connected to the tamper switch, which opens when the cover is opened.

UL NOTE:

To comply with UL Standard 294, connect the tamper terminal to a 24 hour zone in your control panel.

NOTE:

* Available on iREX Plus only

UL NOTE:

Only UL Listed and/or Recognized wire suitable for the application shall be used and the minimum permissible wire size is No. 22 AWG (0.32mm2).

Switch Function Description

1 LED

Operation

ON (default) - LED is activated. The LED turns on when motion is detected.

OFF - LED is disabled.

2 Timer

Reset

Mode

ON (default) - Relay timer resets when motion is detected during the Relay operation
time.

OFF - Relay timer does not reset when motion is detected during the Relay time.

3 Relay

Mode

This switch defines the relay's operation when power is removed from the iREX.

OFF (default) - Fail Secure mode. When power is removed from the iREX a locked door
will remain locked and secured against opening. (This mode should be authorized by
your local authority)

ON - Fail Safe mode. When power is removed from the iREX a locked door will unlock
and be safely opened.

(See Contact Output Wiring)

4, 5, 6

Relay Timer
Activation

Switch

Relay Timer

(seconds)

4

5

6

1/2

OFF OFF OFF

1

OFF OFF ON

2 OFF

ON

OFF

4(default)

OFF ON ON

8 ON

OFF

OFF

16 ON

OFF

ON

32

ON ON OFF

7 Signal

Processing

Determines the detector's PIR detection sensitivity to movement.
ON - High PIR sensitivity
OFF (default) - Low PIR sensitivity.

8, 9, 10

Remote Input
Functions
(See Wiring
options)

Switch

Function

8

9

10

Parallel Door Control (default)

OFF

OFF

OFF

Remote Buzzer Control *

OFF

OFF

ON

Remote iREX Disable *

OFF

ON

OFF

Door Alarm Mode *

OFF

ON

ON

Door Secure Mode *

ON

ON

ON

NOTE:

* Available on iREX Plus only

TECHNICAL SPECIFICATIONS

For UL Standard 294 Compliance:

Power
Voltage

12-30 Volts DC or AC

Current Consumption

8mA standby,
iREX: 30mA max (Relay+LED),
iREX Plus: 50mA max at 12/24 VDC
(including Buzzer)

Relay Output Rating

1A @ 30 volts DC or AC, two form
“C” contacts

Tamper Output Rating

50mA @ 30 volts DC or AC

Buzzer Output (iREX Plus)

85dB with adjustable volume

Output Level at 10ft

69dBA

Detection System
Mounting Height

2.3m - 4.6m (7.5ft – 15ft)

Detection range Width

From 0.6m (2ft) up to 2.4m (7.9ft)

Physical
Dimensions (LxHxD)

177mm x 50mm x 45mm

Weight 150g
Color

Black or White

Environmental
Radio Frequency Interference
(RFI) Immunity

30 V/m from 10 MHz to 2 GHz

Operating Temperature

-20°C to 55°C (-4°F to 131°F)

Storage Temperature

-20°C to 60°C (-4°F to 140°F)

Humidity

Up to 75%

Note: For indoor use only.

ORDERING INFORMATION

Model

Description

iREX 700

iREX Request-to-Exit PIR White/Black

iREX 700P

iREX Plus Request-to-Exit PIR White/Black

1. RFI is not verified by UL
2. IQ remote feature is UL listed when it is controlled by Access
Control units and not burglar alarm units.
3. NFPA 101 requires the use of Fail Safe relay mode. Fail Secure
relay mode should be used where accepted under Local
Authority jurisdiction.
4. Setting of low sensitivity at the mounting height of 15ft and 8.5ft
may affect the maximum range.
5. Wiring methods shall be in accordance with the National Electrical Code

(ANSI/NFPA70), local codes, and the authorities having jurisdiction.

6. If a fail-secure lock is employed, UL Listed panic hardware must be used

to allow exit from the protected area.

7. All interconnected devices must be UL Listed.
8. Unit must be installed indoors within the protected premises.
9. The unit must be powered by a UL294 Listed Access Control, Power

Limited, power supply capable of 4 hour standby.

RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials
and workmanship under normal use for 24 months from the date of production. Because Seller does not install or
connect the product and because the product may be used in conjunction with products not manufactured by the
Seller, Seller can not guarantee the performance of the security system which uses this product. Sellers obligation
and liability under this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable
time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed
or implied, and makes no warranty of merchantability or of fitness for any particular purpose. In no case shall seller
be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied,
or upon any other basis of liability whatsoever. Sellers obligation under this warranty shall not include any
transportation charges or costs of installation or any liability for direct, indirect, or consequential damages or delay.
Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any
persona; injury or property loss by intruder, robbery, fire or otherwise; or that the product will in all cases provide
adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce
the risk of intruder, robbery or fire without warning, but is not insurance or a guaranty that such will not occur or that
there will be no personal injury or property loss as a result. Consequently seller shall have no liability for any personal
injury, property damage or loss based on a claim that the product fails to give warning. However, if seller is held
liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise,
regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the product, which shall
be complete and exclusive remedy against seller. No employee or representative of Seller is authorized to change
this warranty in any way or grant any other warranty.
WARNING: This product should be tested at least once a week.

Contacting RISCO Group
RISCO Group is committed to customer service and product support. You can contact us through our website
(www.riscogroup.com) or at the following telephone and fax numbers:

United Kingdom
Tel: +44-161-655-5500
[email protected]

USA
Tel: +1-631-719-4400
[email protected]

Poland
Tel: +48-22-500-28-40
[email protected]

Italy
Tel: +39-02-66590054
[email protected]

Belgium
Tel: +32-2522 7622
[email protected]

Israel
Tel: +972-3963-7777
[email protected]

Spain
Tel:+34-91-490-2133
[email protected]

Brazil
Tel: +1-866-969-5111
[email protected]

France
Tel: +33-164-73-28-50
[email protected]

China
Tel: +86-21-52-39-0066
[email protected]

All rights reserved. No part of this document may be reproduced in any form without prior written permission from the
publisher.
© RISCO Group 08/09 5IN700PR C

Advertising