RISCO Group iWISE RK815DTBG2 User Manual

Page 2

Advertising
background image

2

FCC Compliance Section (US version):

FCC Part 15 Note:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment to an outlet on a circuit different from that to which

the receiver is connected.

Consult the dealer or an experienced radio/TV technician.

FCC Warning:
The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the
user's authority to operate the equipment.

US Patent Number:
This product is protected under Patent No. US 7,126,476 B2. Other patents
pending.

CE Compliance Section (European and German versions):
Risco Ltd. hereby declares that this equipment is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC. For the CE
Declaration of Conformity please refer to our website: www.riscogroup.com

Applicable countries (European versions):

AT BE CY CZ DK

EE FI FR DE GR

HU IE IT LV LT

LU MT NL PL PT

SE SL ES SK GB

BG RO TR CH NO

RK815DTB2/RK825DTB2 applicable countries (German Version):
AT, CZ, SL, DE, TR, RO, EE

RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to
be free from defects in materials and workmanship under normal use for 24 months
from the date of production. Because Seller does not install or connect the product
and because the product may be used in conjunction with products not
manufactured by the Seller, Seller cannot guarantee the performance of the
security system which uses this product. Seller's obligation and liability under this
warranty is expressly limited to repairing and replacing, at Seller's option, within a
reasonable time after the date of delivery, any product not meeting the
specifications. Seller makes no other warranty, expressed or implied, and makes no
warranty of merchantability or of fitness for any particular purpose.
In no case shall seller be liable for any consequential or incidental damages for
breach of this or any other warranty, expressed or implied, or upon any other basis
of liability whatsoever.
Seller's obligation under this warranty shall not include any transportation charges
or costs of installation or any liability for direct, indirect, or consequential damages
or delay.
Seller does not represent that its product may not be compromised or
circumvented; that the product will prevent any personal injury or property loss by
burglary, robbery, fire or otherwise; or that the product will in all cases provide
adequate warning or protection. Buyer understands that a properly installed and
maintained alarm may only reduce the risk of burglary, robbery or fire without
warning, but is not insurance or a guaranty that such event will not occur or that
there will be no personal injury or property loss as a result thereof.
Consequently seller shall have no liability for any personal injury, property damage
or loss based on a claim that the product fails to give warning. However, if seller is
held liable, whether directly or indirectly, for any loss or damage arising under this
limited warranty or otherwise, regardless of cause or origin, seller's maximum
liability shall not exceed the purchase price of the product, which shall be complete
and exclusive remedy against seller.
No employee or representative of Seller is authorized to change this warranty in
any way or grant any other warranty.
WARNING: This product should be tested at least once a week.


Contacting RISCO Group
RISCO Group is committed to customer service and product support. You can
contact us through our website www.riscogroup.com or as follows:

United Kingdom

Tel:+44-161-655-5500
[email protected]

USA
Te: +1-631-719-4400
[email protected]

Italy
Tel: +39-02-66590054
[email protected]

Brazil
Te:l+1-866-969-5111
[email protected]

Spain
Tel:+34-91-490-2133
[email protected]

China

Tel: +86-21-52-39-0066
[email protected]

France

Tel: +33-164-73-28-50
[email protected]

Poland

Tel: +48-22-500-28-40
[email protected]

Belgium

Tel: +32-2522 7622
[email protected]

Israel

Tel: +972-3963-7777
[email protected]


All rights reserved. No part of this document may be reproduced in any form without
prior written permission from the publisher

RISCO Group 01/2013 5IN1241 C

815DTBG2

815DTBG2

825DTBG2

Programmation ProSYS (Ver 7.xx et supérieure) :

1. Ajouter/Supprimer un détecteur iWISE BUS

 Menu Installateur > [7] Accessoires > [1] Ajout/Suppression Module > [9] Plus... > [5] BUS

Zones.

 Sélectionner l’ID (comme défini par les Dip switches) et définir le type sur iDTG2

2. Assigner le détecteur iWISE BUS à une zone

 Menu Installateur > [2] Programmation Zones > [1] Une par Une > Sélectionner la zone.

 Dans la section Nature, sélectionner > [5] Zone-BUS.

 Sélectionner le numéro ID de zone BUS à assigner à la zone programmée.

3. Programmer l’entrée zone supplémentaire de l’iWISE BUS

 Menu Installateur > [2] Programmation Zones > [1] Une par Une > Sélectionner la zone

 Dans la section Nature, sélectionner de l’option [07] à l’option [11].

 Valider par [#]. Sélectionner la zone BUS pour laquelle l’entrée zone supplémentaire est

paramétrée.

4. Configurer les paramètres du détecteur iWISE BUS (voir tableau)

 Menu Installateur > [2] Programmation Zones > [0] Divers > [3] BUS-Zone Paramètres.

Option de
programmation

Description

LEDS

Définit le mode de fonctionnement des LEDs.

MW Range
(Portée HF)

Définit la portée du canal HyperFréquence.
1) Minimum

3) 50%

5) 85%)

7) Potentiomètre

2) 25%

4) 65%

6) Maximum

Technologie ACT

Définit le mode de fonctionnement de la technologie Anti-Cloak™
(ACT – Anti-Camouflage).

Isolation MW (HF)
Automatique

Définit si le détecteur fonctionnera en mode IRP seul dans le cas
ou il y aurait un défaut HF.

Isolation MW (HF)
@ OFF
(Désarmement)



GreenLine

Le GreenLine est une fonctionnalité qui suit les directives
environnementales en supprimant le surplus d’émission. Cette
fonctionnalité définit si le canal HF sera actif quand le système
est désarmé.

Self Test (Auto Test)

Utilisé pour tester les technologies de détection. Si le test
échoue, un Défaut Auto-test est créé.


Programação da ProSYS (Ver 7.xx ou posterior):

1. Adicionar/Apagar um detector iWISE BUS

 Menu do instalador [7] Acessórios > [1] Adicionar / Apagar módulo > [9] Mais.. > [5] Zonas

de BUS.

 Selecionar ID (como definido nos Dipswitches) e definir como o tipo iDTG2.

2. Alocar o iWISE BUS à uma zona

 Menu do Instalador [2] Zonas > [1] Uma a Uma > Selecionar Zona.

 No menu de Terminação selecione > [5] Zona de BUS.

 Selecione o número da zona de BUS para alocar a zona programada.

3. Programação da entrada de zona do IWISE BUS

 Menu do instalador [2] Zonas > [1] Uma a uma > Selecionar Zona.

 No menu de terminação escolha uma das opções de [07] até [11].

 Apertar [#]. Escolher a zona de BUS que a entrada de zona pertence.

4. Configurar os parâmetros do detector iWISE BUS (Veja tabela)

 Selecionar o menu do instalador [2] Zonas > [0] Diversos > [3] Parâmetros de Zonas de

BUS.

Opções de
Programação

Descrição

LEDS

Habilita/desabilita a operação dos LED´s

Alcance de microondas

Ajusta o alcance do canal de Microondas
1) Mínimo

3) 50%

5) 85%)

7) Trimmer

2) 25%

4) 65%

6) Máximo

ACT

Habilita/desabilita o modo de operação da tecnologia anti-
camuflagem (ACT™).

Inibição automática do
canal de Microondas

Define se o detector irá operar no modo de Apenas Infravermelho
Passivo em caso de problemas do Microondas.

Green Line

Uma característica que segue as diretrizes ambientais, evitando
excesso de emissão. Essa característica desabilita a emissão de
microondas enquanto o sistema estiver desarmado.

Auto Teste

Usado para testar as tecnologias de detecção. Quando existe um
evento de falha de teste, um evento de teste é criado.

ProSYS Programming (Ver 7.xx and above):

1. Add/delete an iWISE BUS detector

 Installer menu [7] Accessories / Install > [1] Add Delete Module > [9] More.. > [5] BUS Zone.

 Select ID (as defined by the Dip switches) and define type as iDTG2.

2. Assign the iWISE BUS detector to a Zone

 Installer menu [2] Zones > [1] One by One > Select Zone.

 Under Termination select > [5] BUS Zone.

 Select the BUS zone number to assign to the programmed zone.

3. Program the zone input on the iWISE BUS

 Installer menu [2] Zones > [1] One by One > Select Zone.

 Under Termination select from options [07] to [11].

 Press [#]. Select the BUS zone that the input zone belongs to.

4. Configure the iWISE BUS detector parameters (see table below).

 Installer menu select [2] Zones > [0] Miscellaneous > [3] BUS Zone Parameters

Parameter

Description

LEDs

Determines the operation of the detector’s LEDs.

MW Sensitivity

Defines the microwave channel range.
1) Minimum

3) 50%

5) 85%)

7) Trimmer

2) 25%

4) 65%

6) Maximum

ACT

Defines the Anti-Cloak™ Technology (ACT) operation mode.

Automatic
Microwave Bypass

Defines if the detector operates in PIR only mode in case of MW trouble.

Green Line

A feature that follows environmental guidelines by avoiding surplus
emission. This feature defines the activation of the microwave channel
while the system is disarmed.

Self Test

Used to test the detection technologies. In the event of a failed test, a
Self Test Trouble is created.


Programmazione ProSYS (Versione 7.xx e successive):

1. Aggiungi/cancella un rivelatore BUS iWISE

 Menù Tecnico [7] Accessori > [1] Agg./Canc.Modulo > [9] Continua.. > [5] Zone BUS.

 Selezionare il numero ID (come impostato dai microinterrutori) e definire il tipo come iDTG2.

2. Assegnazione del rivelatore BUS iWISE ad una Zona

 Menù Tecnico [2] Zone > [1] Una per Una > Selezionare il numero di zona.

 Raggiunta l’opzione Terminazione selezionare > [5] Zona BUS.

 Selezionare il numero ID della zona BUS da assegnare alla zona che si sta programmando

3. Programmazione dell’ingresso di zona aggiuntivo sul rivelatore BUS iWISE

 Menù Tecnico [2] Zone > [1] Una per Una > Selezionare il numero di zona.

 Raggiunta l’opzione Terminazione selezionare una delle opzioni da [07] a [11].

 Premere [#]. Selezionare il numero ID della zona BUS che fa riferimento all’ingresso di zona

che si sta programmando.

4. Configurazione dei parametri del rivelatore BUS iWISE (vedi tabella)

 Nel Menù Tecnico selezionare [2] Zone > [0] Varie > [3] Parametri Zone BUS.

Parametro

Descrizione

LED

Determina il modo di funzionamento dei LED

Portata Microonda

Determina la regolazione della portata del canale MW
1) Minima

3) 50%

5) 85%)

7) Trimmer

2) 25%

4) 65%

6) Massima

ACT

Definisce il modo di funzionamento della Tecnologia Anti-Cloak™ (ACT)

Auto Esclusione
Microonda (MW)

Stabilisce se il canale a microonda deve essere disabilitato
automaticamente se il rilevatore verifica un anomalia di funzionamento
sullo stesso.

Green Line

La funzione Green Line evita emissioni radio superflue nell’ambiente
quando i locali sono occupati. Questa funzione permette la disabilitazione
del canale microonda quando il sistema è disinserito.

Auto Test

Utilizzata per testare le tecnologie di rilevazione. Nel caso il test non vada
a buon fine, verrà registrato in centrale un evento di Auto test fallito.


Programación ProSYS (Ver 7.xx y superior):

1. Añadir/Borrar un detector iWISE BUS

 Menú Instalador > [7] Accesorios > [1] Agregar/Borrar Módulo > [9] Más... > [5] Zonas BUS

 Seleccione el ID (según se haya definido con los microinterruptores DIP) y defina el tipo

como iDTG2.

2. Asignar el detector iWISE BUS a una Zona

 Menú Instalador > [2] Zonas > [1] Una a Una > Seleccione la Zona

 En el apartado Terminación, seleccione la opción [05] Zona BUS.

 Seleccione el ID del detector BUS que se va a asignar a la zona programada.

3. Programar la entrada de zona adicional del IWISE BUS

 Menú Instalador > [2] Zonas > [1] Una a Una > Seleccione la Zona.

 En el apartado Terminación, seleccione una de las opciones de la [07] a la [11].

 Presione [#]. Seleccione el ID del detector BUS al que pertenece la entrada de zona.

4. Configuración de los parámetros del detector iWISE BUS (ver tabla).

 Menú Instalador > [2] Zonas > [0] Varios > [3] Parámetros Zona BUS.

Opción de programació Descripción
LEDs

Define el modo de funcionamiento de los LEDs

Alcance del Microondas Define el alcance del canal microondas

1) Mínimo

3) 50%

5) 85%)

7) Potenciómetro

2) 25%

4) 65%

6) Máximo

ACT

Define el modo de funcionamiento de la tecnología Anti-Cloak™(ACT).

Anulación Automática
del Microondas

Define si el detector funcionará sólo en modo PIR en caso de fallo del
MW.

Green Line

Característica que sigue las directrices medioambientales, evitando
emisiones superfluas. Esta característica define si se activará el canal
microondas mientras el sistema está desarmado.

Auto Test

Utilizado para probar las tecnologías de detección. Cuando un test falle,
se generará un Problema de Fallo de Test.

Prova de Moviento

Prueba de detección

Test de marche

Walk Test

Test Sensore

MW Sensitivity

Portata Microonda

Alcance del Microondas

Portée HF

Alcance de microondas

1

2

3

x

x

RK815DTB2

RK815DTB2

RK825DTB2

Advertising
This manual is related to the following products: