RISCO Group iWISE®, iWISE® QUADSEQ Grade 3 User Manual

Page 2

Advertising
background image

Page 3



Jumper Position Function

Used to determine the sensitivity of the center PIR area.



High

High Sensitivity selection

SENSITIVITY

(Default)

Low: Low Sensitivity selection

Used to determine the polarity of the external input.



(Default)



12V: 12v has to be connected in order to disable the LED’s.

GND or N.C. has no influence on the LED’s status. (see self test jumper configuration)

LED INPUT

0V

0V: The GND has to be connected in order to disable the LED’s.

12v or N.C. has no influence on the LED’s status. (see self test jumper configuration)

Used to determine the relay’s activation logic.



INT: The detector’s alarm activation is determined by the detector’s internal logic. Intruder detection on
one of the PIR’S detection areas (side or center) activates the appropriate LED only.
If both PIR’S (side and center) are triggered within a time window of 2 minutes, then both side and
center relays are activated

CONF

(Default)



EXT: The security panel determines the detector’s alarm activation. Intruder detection on one of the
detection zones (side or center) activates the appropriate LED and Relay only.

Used to determine the operation of the detector’s LEDs



(Default)

ON: LEDs are enabled

Note

:

When an activation signal (see LED Activation jumper for settings) is applied to the LED input of the
terminal block, LEDs will be disabled.

LED

OFF: LEDs are disabled

Used to test the PIR channels functionality

LOC (Local Self Test): If there is no alarm detection within 1 hour from previous detection, the detector
will self test both PIR channels.
In case the local self test fails, the FAULT/AM Relay is activated for a period of 2.5 seconds.

SELF TEST

(Default)

REM (Remote Self Test): Remote Self Test is activated when the LED terminal input is switched from
DISABLE to ENABLE mode (see LED Activation jumper for settings).
In case the remote self test passes, the Alarm Relays are activated for a period of 5 seconds.
In case the test fails, FAULT/AM Relay is activated for a period of 2.5 seconds.

EOL
RESISTORS
JUMPERS

The jumpers are used when connecting the detector to a DEOL or TEOL Zone. The jumpers allow the selection of
TAMPER, TAMPER (upper), ALARM CENTER and ALARM SIDE E.O.L resistors (1K, 2.2K, 4.7K, 5.6K or 6.8K),
according to the control panel. An additional double jumper allows the connection of 12K FAULT/AM E.O.L resistor (see
EOL Resistors Scheme).

TAMPER

EOL

JUMPERS

1K

No
Resistor
(Default)

2.2K

4.7K 5.6K

6.8K

TAMPER (upper) EOL JUMPERS

1K

Short
(Default)

2.2K

4.7K

5.6K

6.8K

NONE

ALARM

CENTER

JUMPERS

1K

No
Resistor
(Default)

2.2K

4.7K

5.6K

6.8K

ALARM

SIDE EOL

JUMPERS

1K

No
Resistor
(Default)

2.2K

4.7K

5.6K

6.8K

FAULT/AM

EOL

JUMPERS

12K

No
Resistor
(Default)

EOL Resistors Scheme

Note:

Side & Center area can be connected to DEOL or
TEOL areas on the panel as illustrated below.


TAMPER

ALARM

CENTER

ALARM

SIDE

TAMPER

+12-

LED

FAULT/AM

TEOL ZONE

FAULT AM

ALARM

CENTER

+12-

LED

ALARM SIDE

TAMPER FAULT AM

TAMPER

DEOL/TEOL

ZONE

ALARM SIDE

ALARM

CENTER

TAMPER

ALARM

CENTER

+12-

FAULT AM

LED

DEOL ZONE

ALARM

SIDE

TAMPER

ALARM

CENTER







Page 4



Walk Test

Two minutes after applying power (warm-up period), walk test the Detector over the entire protected area to verify proper operation of the
unit.
Important: Always close the front cover prior to applying power to the detector.]

7HFKQLFDO6SHFLILFDWLRQ

Electrical

Current consumption

12mA at 12VDC, 39mA at
12VDC (max. with all LEDs ON)

Voltage requirements

9 -16VDC

Alarm contacts

24VDC, 0.1A

Tamper contacts

24VDC, 0.1A

FAULT/AM contacts

24VDC, 0.1A

Environmental

RF immunity

According to EN50130-4

Operating temperature

-20°C to 55°C (-4°F to 130°F)

Storage temperature

-20°C to 60°C (-4°F to 140°F)

Physical

Size

127.6 x 64.2 x 46.6 mm
(5 x 2.5 x 1.84 in.)

Weight

115 gr. (4 oz)

2UGHULQJ,QIRUPDWLRQ

Part Number

Description

RK800QS0000A

iWISE QUADSEQ Grade 3

RISCO Group Warranty

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24
months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products
not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product. Seller's obligation and liability under
this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any product not meeting the
specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of fitness for any particular purpose.
In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other
basis of liability whatsoever.
Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential
damages or delay.
Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any persona; injury or property loss by
burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly installed and
maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not assurance or a guarantee that such will not occur or that there
will be no personal injury or property loss as a result.
Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning. However, if
seller is held liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise, regardless of cause or origin,
sellers maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or
representative of Seller is authorized to change this warranty in any way or grant any other warranty.




United Kingdom

Tel: +44-161-655-5500
[email protected]

Italy

Tel: +39-02-66590054
[email protected]

Spain

Tel: +34-91-490-2133
[email protected]

France

Tel: +33-164-73-28-50
[email protected]

Belgium

Tel: +32-2522-7622
[email protected]

USA

Tel: +305-592-3820
[email protected]

Brazil

Tel: +55-11-3661-8767
[email protected]

China

Tel: +86-21-52-39-0066
[email protected]

Poland

Tel: +48-22-500-28-40
[email protected]

Israel

Tel: +972-3-963-7777
[email protected]

























PD6662, EN50131-1, EN50131-2-2 Grade 3 Class II

© RISCO Group 12/08 5IN800QS B