3.2.2

Check the voltage of the battery with a digital voltmeter. Locate the voltage reading
of the battery in the table below and charge the battery for the recommended time
interval to bring the charge up to a full charge of 12.6 volts or greater.

IMPORTANT: Make sure the negative battery cables are disconnected and the
battery charger used for charging the battery has an output of 16 volts and 7
amps or less to avoid damaging the battery (see chart below for recommended
charger settings).

Voltage

Reading

Percent

Charge

Maximum

Charger Settings

Charging Interval

12.6 or greater

100%

16 volts/7 amps

No Charging Required

12.4 – 12.6

75 – 100%

16 volts/7 amps

30 Minutes

12.2 – 12.4

50 – 75%

16 volts/7 amps

1 Hour

12.0 – 12.2

25 – 50%

14.4 volts/4 amps

2 Hours

11.7 – 12.0

0 – 25%

14.4 volts/4 amps

3 Hours

11.7 or less

0%

14.4 volts/2 amps

6 Hours or More

CAUTION

POTENTIAL HAZARD

If the ignition is in the “ON” position there is potential

for sparks and engagement of components.

WHAT CAN HAPPEN

Sparks could cause an explosion or moving parts

could accidentally engage causing personal injury.

HOW TO AVOID THE HAZARD

Be sure ignition switch is in the “OFF” position before

charging the battery.

3.2.3

Connect the negative battery cables.

NOTE: If the positive cable is also disconnected, connect the positive (red)

cable and the red wire to the positive terminal on the battery first, then connect
the negative (black) cable and white/white wire to the negative terminal on the
battery (red wire and white/white wire are only on some units). Slip insulator boot
over the positive terminal.

NOTE: If time does not permit charging the battery, or if charging equipment is
not available, connect the negative battery cables and run the vehicle
continuously for 20 to 30 minutes to sufficiently charge the battery.

For Serial Nos. 251,999 and lower.

The machine is shipped with a dry battery.

3.2.4

Remove battery from machine. Tilt seat up to gain access to the battery.
Disconnect battery cables – negative (black) cable first. Remove battery
hold-down and lift battery out.