RIGOL DS6000 Series User Manual

Page 61

Advertising
background image

RIGOL

RP1003C/RP1004C/RP1005C User’s Guide

17

Rated Power

5.6W

Supply Voltage

+12V±0.5V

Maximum Rated Voltage

300V, CAT I (insulated conductor)

Gain Accuracy Period

1 year (opening/closing up to 10,000 times)

Effect of External
Magnetic Fields

≤20mA (DC and 60Hz, magnetic field of
400A/m)

RP1004C:

Bandwidth

DC to 100MHz (-3dB), refer to Appendix 1
Amplitude Characteristics
(RP1004C)

Rise Time

≤3.5ns

Linear Response Range of
Input Current

30Arms, refer to Appendix 2 Relation
between Max Input Current and
Frequency
(RP1004C)

Maximum Peak Current

50A peak, non-continuous

Gain

0.1V/A

Gain Accuracy

±1.0%rdg±1mV, ≤30A
±2.0%rdg, 30A to 50A peak (DC and 45Hz
to 66Hz, within the linear response range of
the input current)

Noise

≤2.5mArms (for 20MHz band measuring
instrument)

Input Impedance

Refer to Appendix 3 Input Impedance
(Typical)
(RP1004C)

Gain Accuracy Drift

≤±2% (0℃ to 40℃ temperature, input of
50Hz, 30A)

Rated Power

5.3W

Supply Voltage

+12V±0.5V

Maximum Rated Voltage

300V, CATI (insulated conductor)

Gain Accuracy Period

1 year (opening/closing up to 10,000 times)

Advertising