To connect to power, Power-on inspection – RIGOL DP832A User Manual

Page 55

Advertising
background image

RIGOL

DP800A Quick Guide

15

To Connect to Power

1. Input power requirement

DP800A series power supply can accept three kinds of AC power supplies:

50Hz–60Hz frequency; 100V, 115V and 230V voltages.

2. Check the voltage selector at the rear panel

Before connecting to power, make sure that the setting voltage of the voltage

selector at the rear panel matches the input voltage.

3. Check the fuse

When the instrument leaves factory, proper fuse is installed. Please check

whether the fuse matches the input voltage according to the “Input Power

Requirement” at the rear panel.

4. Connect the instrument power cord

Connect the instrument to AC power supply using the power cord provided in

the accessories.

WARNING

To avoid electric shock, make sure that the instrument is correctly

grounded.

Power-on Inspection

Press the power switch at the front panel and the instrument executes self-test. If

the instrument passes the self-test, the welcome interface will be displayed;

otherwise, the corresponding self-test failure information (including TopBoard,

BottomBoard, Fan and Temperature) will be displayed.

Tip

When turn the instrument on again after turn it off, please make sure the time

between the two operations are larger than 5s.



Advertising
This manual is related to the following products: