background image

o)

P)

q)

r)

s)

t)

u)

v)

w)

Align No. 5 cam with previously establish-

ed top stop mark by rotating cam
a d j u s t i n g k n o b .

Maintain No. 5 cam alignment by holding

adjusting knob. Rotate No. 3 cam so that

indicator groove lines up with the fiber

cam follower on LS3 breaker point. Refer

to Figure 4. This alignment must be done

with the crankshaft at top dead center.

Tighten inner jam nut and lock in place

with outer jam nut. Do not back inner jam

nut off to meet outer jam nut.

Reinspect cam positions.

Make sure that the ground connection is

tight, (see Figure 6).

Position felt seal (34) and replace end

cap (31).

Turn electrical power on when press is

ready to run.

If top stop position must be readjusted,

follow instructions given in Paragraph 2.3.

Breaker Point Adjustment:

When making the following adjustment, exer-
cise caution with the wire leads to make sure

they are secure and not shorted out.

!

Caution:

Make sure the electrical power is turned off

before proceeding to avoid possible injury.

a)

Refer to Figure 6 and loosen the two

breaker point mounting screws (44).

b)

Shift the breaker point assembly (23) to

establish the correct gap.

c)

With the opening gap properly set,
retighten the mounting screws (44).

Measure gap of LS4 by repeating. Steps

“g” through “j”.

d)

Make sure that the ground connection is

tight (see Figure 6)

e)

If points cannot be adjusted to proper gap

or are pitted, they must be replaced.

Follow instructions given in Paragraph 3.1.3.

f)

After all breaker point adjustments have
been made, refer to Paragraph 3.1.1 and
complete Steps “p” through “v”.

3.1.3 Breaker Point Replacement:

a)

Identify all wire leads before detaching

them from breaker point terminals.

b)

Disconnect the wire leads from the

breaker point being replaced.

c)

Remove the two breaker point mounting

screws (44) and discard the old breaker
point.

d)

Coat the fiber cam follower with the

grease lubricant furnished with the new

breaker point.

e)

Install the new breaker point.

f )

Attach the wire leads to the breaker point.

g)

Adjust the breaker point gap as outlined

in Paragraph 3.1.2.

3.2

Bearings and Seals Replacement:

3.2.1

The bearings in both types of timers and the

rotating seals (16 and 19) in the timing

rotorseal are not considered to be field’
replaceable items and it is recommended that

the units be returned to the factory.

For dimensional information, request
Form PP3000.

For additional information, contact Eaton

Corporation, Industrial Drives Operations,
Airflex Division, 9919 Clinton Road, Cleveland,

Ohio 44144, telephone (216) 281-2211.