25) ADJUST GOVERNOR SYSTEM

Governor system is centrifugal flyweight

type . Governor weight is installed into

governor gear driven by crankshaft .

Governor weight movement is transferred

to throttle lever via governor shaft and

lever .

Engine speed is maintained at the constant

speed by throttle valve opening and closing

operation in accordance with load condition

of engine .

(1) Push speed control lever all the way to the

high speed position and fix it by tightening

nut .

(2) Check that governor lever is pulled by

governor spring and throttle valve is fully

open .

(3) Turn governor shaft counterclockwise all

the way and tighten lock bolt to secure the

lever on the shaft .

26) BLOWER HOUSING

Attach blower housing to crankcase with

control box commonly fixed .

Connect fuel pipes onto blower housing .

BLOWER HOUSING(Front)

M6 x 14 Flange bolt : 4 pcs .

BLOWER HOUSING(Side)

M6 x 18 Flange bolt : 2 pcs .

M6 x 14 Flange bolt : 2 pcs .

GOVERNOR LEVER

GOVERNOR SHAFT

BLOWER

HOUSING

(Side)

Connect the wiring to

the electric starter.

BLOWER

HOUSING

(Front)

Tightening torque

3.9 - 5.9 N•m

(40 - 60 kgf•cm)

(2.9 - 4.3 ft•lb.)

Tightening torque

2.9 - 4.9 N•m

(30 - 50 kgf•cm)

(2.2 - 3.6 ft•lb.)