Power management system, Ac input power, Power management function – Elo TouchSystems AMM15TK2-TEW User Manual

Page 15

Advertising
background image

15

Power Management Function


The monitor is equipped with the power management function which automatically reduce the
power consumption when not in use in three power level modes.

Stand-by Mode


The monitor goes into stand-by mode when the horizontal sync signal is off for about 10
seconds. In this mode, the screen goes off and the power LED blinks for 1 seconds On and 1
second Off. The screen is displayed after the horizontal sync signal is restored.


Suspend Mode


The monitor goes into suspend mode when the vertical sync signal is off for about 10 seconds.
The power consumption during this is less than 8 W. In this mode, the screen goes off and the
power LED blinks for 1 seconds On and 1 second Off. The screen is displayed after the vertical
sync signal is restored.


Off Mode


The monitor goes into power-off mode when the vertical and horizontal sync signals are off for
about 10 seconds. In this mode, the screen goes off and the power LED blinks for 1 seconds On
and 1 second Off. The screen is displayed after the vertical and horizontal sync signals are
restored.




Power Management System


The AMM15TK2 Series Medical Monitor complies with the VESA DPMS power management
proposal. The VESA DPMS proposal provides four phases of power-saving modes by detecting
the horizontal sync signal as shown in the table blow.

Mode

DC Input Power
(monitor only)

AC Input power
(incl. AC adapter)

LED Status

On

28.0 W max.

37 W max.

Steady Green

Standby

4.5 W max.

6W max

Blinking Green

Suspend

4.5 W max.

6W max

Blinking Green

Off

4.5 W max.

6W max

Blinking Green