Check to make sure magnetic breaker is in the
“ON” position
After making sure that the total wattage of the
electrical appliance is within permissible limits
and there are no defects in the appliance, turn the
magnetic breaker to the “ON” position.
If breakers continue to actuate, consult your
nearest servicing dealer.
Check AC terminals for loose connection
Secure connection if necessary
Check to see if engine starting was attempted
with appliances already connected to the
generator
Turn off switch on the appliance, and disconnect
cable from receptacle. Reconnect after generator
has been started properly.
Low power
Carbon brushes are excessively worn.
TROUBLESHOOTING
When generator’s engine fails to start after several attempts, or if no electricity is available at the output socket, check
the following chart. If your generator still fails to start or generate electricity, contact your nearest SUBARU Industrial
Power Products dealer or service center for further information or corrective procedures.
When Engine Fails to Start:
Check if choke lever is in its proper position
Set the choke lever to “START” position - See
“Operating Procedures”
Check if fuel valve is open
If closed, open fuel valve
Check fuel level
If empty, re
fi
ll fuel tank making sure not to over
fi
ll
Check if engine switch is OFF
Turn engine switch to ON
Check to make sure generator is not connected
to an appliance
If connected, turn off the power switch on the
connected appliance and unplug
Check spark plug for loose spark plug cap
If loose, push spark plug cap back into place
Check spark plug for contamination.
Remove spark plug and clean electrode.