When No Electricity Is Generated at Receptacle:

Check to make sure magnetic breaker is in the

“ON” position

After making sure that the total wattage of the

electrical appliance is within permissible limits

and there are no defects in the appliance, turn the

magnetic breaker to the “ON” position.

If breakers continue to actuate, consult your

nearest servicing dealer.

Check AC terminals for loose connection

Secure connection if necessary

Check to see if engine starting was attempted

with appliances already connected to the

generator

Turn off switch on the appliance, and disconnect

cable from receptacle. Reconnect after generator

has been started properly.

Low power

Carbon brushes are excessively worn.

TROUBLESHOOTING

When generator’s engine fails to start after several attempts, or if no electricity is available at the output socket, check

the following chart. If your generator still fails to start or generate electricity, contact your nearest SUBARU Industrial

Power Products dealer or service center for further information or corrective procedures.

When Engine Fails to Start:

Check if choke lever is in its proper position

Set the choke lever to “START” position - See

“Operating Procedures”

Check if fuel valve is open

If closed, open fuel valve

Check fuel level

If empty, re

ll fuel tank making sure not to over

ll

Check if engine switch is OFF

Turn engine switch to ON

Check to make sure generator is not connected

to an appliance

If connected, turn off the power switch on the

connected appliance and unplug

Check spark plug for loose spark plug cap

If loose, push spark plug cap back into place

Check spark plug for contamination.

Remove spark plug and clean electrode.