Thermo Pride DryR22 (LX-13) User Manual

Page 8

Advertising
background image

8

For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the

Product Catalog Section.

FIGURE 8: Thermostat Chart - Single Stage AC with PSC Air Handler

AC 1A

Single Stage Air Conditioner – PSC Air Handler

C

24 – Volt Common

Y

Compressor

SINGLE STAGE

AIR CONDITIONER

SINGLE STAGE

AIR CONDITIONER

HM1

Humidistat

Y

Full Stage Compressor

G

Fan

*PP11C70224

THERMOSTAT

RH

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

W

Full Stage Heat

Clipping Jumper W914 for

electric heat on thermostat

is not necessary

MA

SHP

AHP

ID MODELS

Other Part Numbers:

SAP = Legacy

265902 = 031-09167

2

Part Numbers:

SAP = Legacy

159480 = 031-09156

1

COM

24 – Volt Common

R

24 – Volt Hot

W2

Second Stage Heat

O

Reversing Valve

Energized in Cool

X/L

Malfunction Light

HUM

Humidity Switch

Open on Humidity Rise

PSC

AIR HANDLER CONTROL

G

Fan

PSC

AIR HANDLER

1

EAC(24 VAC out)

Electronic Air Cleaner

HUM OUT

(24 VAC out)

Humidifier

Y1

Single Stage Compressor

Y/Y2

Second or Full

Stage Compressor

W1

First Stage Heat

24VAC Humidifier

(Optional)

24VAC

Electronic Air Cleaner

(Optional)

Y

Compressor Contactor

SINGLE STAGE

AIR

CONDITIONER

SINGLE STAGE

AIR CONDITIONER

Move HUM STAT

jumper to “YES”

if humidistat is to be used.

Refer to AH documentation

for W1 and W2 electric

heat staging options.

Advertising