Thermo Pride Gas/Propane Furnace ECM CHX1 User Manual

Page 9

Advertising
background image

All installations and services must be performed by qualified service personnel.

7

“Hunts” or “puffs” at high CFM (speed)

Does removing panel or filter reduce “puffing”?

! Reduce restriction
! Reduce max airflow

Evidence of Moisture

Motor failure or malfunction has occurred and
moisture is present

Replace motor and perform Moisture Check

Evidence of moisture present inside air mover

Perform Moisture Check




DO DON’T

Check-out motor, controls, wiring and
connections thoroughly before replacing motor

Automatically assume the motor is bad.

Orient connectors down so water can’t get in
! Install “drip loops”

Locate connectors above 7 and 4 o’clock
positions

Use authorized motor and control model #’s for
replacement

Replace one motor or control model # with
another (unless an authorized replacement)

Keep static pressure to a minimum:
! Recommend high efficiency, low static

filters

! Recommend keeping filters clean
! Design ductwork for min static, max

comfort

! Look for and recommend ductwork

improvement, where necessary, in
replacement

Use high pressure drop filters – some have ½”
H

2

O drop!

Use restricted returns

Size the equipment wisely

Oversize system then compensate with low
airflow

Check orientation before inserting motor
connectors

Plug in power connector backwards

Force plugs





Moisture Check

Connectors are orientated “down” (or as recommended by equipment manufacturer)

Arrange harnesses with “drip loop” under motor

Is condensate drain plugged?

Check for low airflow (too much latent capacity)

Check for undercharged condition

Check and plug leaks in return ducts, cabinet



Comfort Check

Check proper airflow settings

Low static pressure for lowest noise

Set low continuous-fan CFM

T’stat in bad location?


Advertising