Fluidyne Control Systems 6780 Series Evac And Fill Liquid Dispensing System User Manual

Specifications features introduction details, Dimensions

Advertising
background image

Specifications

Features

Introduction

Details

The Series 6780 Dispensing System is specially designed
for 100% air bubble free filling of critical automotive sub
assemblies like brake, clutch, power steering and coolant.
Evacuation levels of up to 0.5 mbar are achivable along
with positive pressure up to 3.0 bar. The machine apart
from filling various liquids also provides excellent quality
test method of leak testing in all critical assemblies.

Machine Cycles Evacuation/Filling/Suck Back/Gun purge
Main Vaccum 0.5 mbar minimum
Filling Pressure Up to 3.5 bar adjustable.
Built In Liquid Reservoir 60 ltr capacity with deareation device
Vaccum Pumps And Sensors Leybold Germany Make
Filling Pumps And Pneumatics SMC Japan Make
PLC / HMI Mitsubishi / Siemens / Allen Bradley
Switch Gear And Motor Siemens Make
Power Supply AC 440V 3 – 2KW connected load.
Nozzle To suit liquid reservoir design in vehicles.
Alarm Diagnostic Alarm for easy maintenance

o/

Dimensions

1100.0

2

1

0

0

.0

1200.0

1200.0

REAR VIEW

FRONT VIEW

LEFT HAND VIEW

:
:
:
:
:
:
:
:
:
:
:

Glass Windows
to TPM Norms

Nozzle For Power Steering
Oil Filling

Nozzle For Clutch
Oil Filling

Fluidyne Control Systems (P) Ltd.

S. No. 79/2,Plot No.12, Near Agarwal Godown, Shivne,
Pune-411 023. India
Tel.: 020-25290504, 25290870 Fax: 020-25292773
E-mail: [email protected]

Series 6780 : Evac And Fill
Liquid Dispensing System

For Brake Oil / Clutch Oil / Power Steering Oil / Coolant Filling Applications
3 Wheeler / 4 Wheeler / Heavy Vehicle Assembly Lines

www.fluidyne.co.in

·

·

·

·

·

·

High evacuation up to 0.5 mbar suitable for braking systems.
Leak check during Evacuation cycle for vaccum.
Leak check during Filling cycle for positive pressure.
Liquid suck back for maintaining oil level in reservoir.
Self test for main vaccum pump efficiency.
Light weight dripless nozzle.
Fully automatic operating cycle, zero operator interference.
Diagnostic alarm for easy maintenance and system fault finding.
Compact size design confirms to TPM standards.

·

·

·

Advertising