Ericsson Scan And System Portable Radios LPE-200 User Manual

Page 20

Advertising
background image

AE/LZB 119 1902 R1A

20

Table 1 - General Troubleshooting

Symptom

Possible Cause/Action Required

Completely Inoperative (no
display or audio on power up)

Power Supply Problem?
1. Check battery voltage with a voltmeter.
2. Charge battery or replace battery.
3. Check to be sure battery contacts are not broke or bent.
4. Clean battery contacts.
5. Check Fuse (F190).

At power -up an error
message is displayed.

1. See the Error Message Tables in the following pages for

type of error and for a probable solution.

2. Always attempt to reprogram the personality and flash

using the EDACS-3 PC Programmer.

Receiver inoperative or weak.

1. Channel Guard or Type 99 Enabled?
2. Defective antenna/ or antenna switch assembly - replace

antenna/ or antenna switch assembly.

3. Main Board failure?

•

Return to Lynchburg Depot for repair (recommended)

or

•

Troubleshoot Main Board using the test point diagrams
in Figure 8. Replace or repair board as required.

Transmitter inoperative or
low power

1. Programmed Incorrectly - check personality.
2. Weak battery - check voltage
3. Defective antenna/ or antenna switch assembly - replace

antenna/ or antenna switch assembly.

4. PA Module failure - replace PA Module.
5. Main Board failure?

•

Return to Lynchburg Depot for repair (recommended)

or

•

Troubleshoot Main Board using the test point diagrams
in Figure 8. Replace or repair board as required.

Transmitter and Receiver
Inoperative on some channels

1. Programmed Incorrectly - check personality.
2. Main Board failure?

•

Return to Lynchburg Depot for repair (recommended)

or

•

Troubleshoot Main Board using the test point diagrams
in Figure 8. Replace or repair board as required.

Advertising