Timing Parameters - AC Electrical Characteristics
(VCC=VDD1=3.3V, VDD2 = 10V, GND = VSS1 = VSS2 = 0V, Ta=25ºC)
Item
Symbol
Min.
Typ.
Max.
Unit
CLK Frequency
F
CLK
–
25
40
MHz
CLK Pulse Width
T
CPH
25
–
–
ns
Data Set-up Time
T
SU
4
–
–
ns
Data Hold Time
T
HD
2
–
–
ns
Propagation Delay of DIO2/1
T
PHL
6
10
15
ns
Time That The Last Data to LD
T
LD
1
–
–
T
CPH
Pulse Width of LD
T
WLD
2
–
–
T
CPH
Time That LD to DIO1/2
T
LDS
5
–
–
T
CPH
POL Set-up Time
T
PSU
6
–
–
ns
POL Hold Time
T
PHD
6
–
–
ns
OE Pulse Width
T
OEV
1
–
–
µs
CKV Pulse Width
T
CKV
500
–
–
ns
STV Set-up Time
T
SUV
400
–
–
ns
STV Hold Time
T
HDV
400
–
–
ns
Horizontal Display Period
T
HDP
–
640
–
T
CPH
Horizontal Period Timing Range
T
HP
–
800
–
T
CPH
Horizontal Lines Per Field
T
V
520
525
640
T
HP
Vertical Display Timing Range
T
DV
–
480
–
T
HP