Part 5

Maintenance

5.2.5

Stopping CA-dryer
during operation:

Cause

- Stopping of CA-dryer by

installed electric start and
protection device (Klixon) at
the refrigerant compressor
due to overload

5.2.5.1 CA-volume flow too

high

5.2.5.2 CA-inlet temperature

too high

5.2.5.3 Room temperature too

high

5.2.5.4 Defective fan or cooling

water regulator (water-
cooled version)

5.2.5.5 Condenser polluted

5.2.5.6 Operating pressure too

low

Remedy

- eliminate cause of trouble, see 3.5 or call for service

- the CA-dryer will return to operation mode automati-

cally after protection device has cooled down.
Note: The immediate restarting of the unit is not pos-
sible because the protection device requires a mini-
mum time to cool down to an admissible operating
temperature.

Reduce volume flow
Check whether CA-dryer´s capacity is properly selected,
increase CA-dryer´s capacity

Check aftercooler with separator and drain behind the
compressed air compressor, install if not present

Ensure proper ventilation of CA-dryer´s location

Replace fan or cooling water regulator resp., call for serv-
ice

Clean condenser

Increase operating pressure, check whether CA-dryer´s
capacity is properly selected